Installation with cabinets
Check location where the range will
be installed for proper electric and
gas supply, and stability of the floor.
The dimensions shown here
must be used and are minimal
unless otherwise stated. These
measurements do not allow for any
clearance below the cooking top or
at the rear of the range.
Contact surface must be solid and
level.
Things to remember:
Do not seal the range to side
cabinets.
Do not pinch the power supply
cord between the range and
rear wall.
If cabinet depth is greater than
25", the oven front frame must
extend beyond cabinet front by
1/2" minimum (See Fig. 1).
All openings in the wall or
floor where the range is to be
installed must be sealed.
installation beside wall
If installing beside a wall, the
minimum distance to combustible
wall on either side of range above
36" height should be according to
the BTU of the largest burner (See
Fig 2).
36 _
Std.
iii:_iii
16 _
Min. to cabinets on
either side of range
30-
30- I ;
Min. height from L ............
141_Max. cooktop to cabinets_
Recommended area for thru
the floor connection of gas
pipe stub and shut-off valve.
"15"
* Models without self=clean feature
may have an additional 7 inches
clearance from the floor.
Recommended
area for 120V outlel
on rear of wall and
area for thru the
wall connection of
pipe stub and shut-
off valve.
Fig. 1
48-1/2"
max
36_+1/8"
(Adjustable)
29-1/4"
door
closed
* 9500 BTU or less 2" "_
10,000 - 16,999 BTU 3" |
17,000 BTU or greater 5" ,9
Fig. 2
4
Fig. 3