8.2 Built-in hobs
Only use the built-in hobs after you
assemble the hob into correct built-in
units and work surfaces that align to the
standards.
8.3 Connection cable
The hob is supplied with a connection
cable.
To replace the damaged mains cable
use the following (or higher) mains
cable type: H05V2V2-F T min 90°C.
Speak to your local Service Centre.
8.4 Attaching the seal
1. Clean the worktop around the cut out
area.
2. Attach the supplied seal stripe to the
lower edge of the hob along the outer
edge of the glass ceramic. Do not
extend it. Make sure that the ends of
the seal stripe are located in the
middle of one side of the hob.
3. Add some mm when you cut the seal
stripe to the length.
4. Push the two ends of seal stripe
together.
8.5 Assembly
min.
50mm
min.
500mm
min.
2mm
min. 2 mm
A
B
A
12 mm
28 mm
38 mm
B
57 mm
41 mm
31 mm
min
30 mm
min. 500 mm
< 20 mm
> 20 mm
min. 2 mm
A
B
A
12 mm
28 mm
38 mm
B
57 mm
41 mm
31 mm
min. 500 mm
www.electrolux.com14