ELECTRmCAL REQUIR MEHTS
We recommend that you have the electrical hookup of
your counter unit done by a qualified electrician. After
installation, have the electrician show you where your
disconnect ts located.
Check with you r local utilities for electrical codes which
apply in your area. Failure to wire your unit according to
governing codes could result in a hazardous condition.
If there are no local codes, your counter unit must be
wired and fused to meet the requirements of the
NATIONAL ELECTRICAL CODE, ANSt/NFPA NO. 70-
1990. You can get a copy by writing:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
You must use a three-wire, single-phase A. C. 208Y/120
Volt or 120f240 Volt, 60 Hertz electrical system. If you
connect to aluminum wiring, properly installed
connections listed for use with aluminum and
copper wiring must be used.
Use aminimum wire size of No. 10 copper wire protected
with a 30 Amp. fuse or circuit breaker for' both 208Y/120
Volt and 120/240 Volt electrical systems.
INSTALLATION
Before installing the counter unit or moving itto another
location, have the electrician verify:
. That your home is provided with adequate electrical
service.
That the addition of the counter unit witl not overload
the household circuit on which it is used.
Cut the opening in the countertop. Be sure to maintain
cutout dimensions and minimum clearances as shown
on previous page. To minimizechipping ofthe countertop
you can apply masking tape before you make the cut.
Install an approved junction box where it will be easily
reached through the front of the cabinet where the
counter unit will be located. The counter unit has 3 feet
of conduit_
IMPORTANT: The junction box must be located
where it will allow considerable slack in the
conduit for serviceability, See Fig. 3.
Install the counter unit in the cutout opening. Note: If
the unit is being installed in a blind counter (one with no
cabinet opening below), wire connections must be made
before putting the unit into the cutout.
Secure the tub of the counter unit to the counter with the
wood screws shipped with the unit.
ELECTRICAL CONNECTIONS
The electrical power to the supply line
must be shut off while line connections
are being made.. Failure to do so could
result in serious injury or death.
When making the wire con nections, use the entire length
conduit provided (3 feet)_ The conduit must not be cut.
Connect the red and black leads from the counter unit
conduit to the corresponding leads in the junction in the
junction box.
The bare ground wire in the conduit is connected to the
counter unlt frame. Connect the other end of this wire to
a properly grounded cold water pipe or use another
approved grounding method.
A white (neutral) wire is not needed for this unit. The
white lead from the household electrical supply can be
taped and terminated in the junction box.
BE SURE THIS CUT DOES NOT
INTERFERE WITH CABINET
STRUCTURE AT FRONT
16" MIN.
CM)
Fig.3
NEINS45-1