Loading ...
Loading ...
Loading ...
28
AC Line Voltage: Single phase 120V, 60Hz, AC only
AC Power Required: 1650 W 14.3 amps. (FGMV205KB,FGMV205KF,FGMV205KW
FPMV189KF)
Output Power*: 1000 watts
Frequency: 2450 MHz
Outside Dimensions (including handle): 29
15
/16”(W) x 17
1
/16”(H) x 18
15
/32”(D)
Cavity Dimensions: 22
1
/2”(W) x 10
1
/16”(H) x 14
31
/32”(D)
Microwave oven Capacity**: 2.0 Cu.Ft.
Weight: Approx. (net) 61 lb, (gross) 73 lb
Work/Night Light: 2 bulbs 20w each (incandescent light bulbs)
SERVICE CALL CHECK
SPECIFICATIONS
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
A Does the oven light come on? YES ____ NO ____
B Does the cooling fan work?
(Put your hand over the left side of louver.)
YES ____ NO ____
C Is the water in the oven warm? YES ____ NO ____
If A is "NO", then you need to check light bulb. See
page 27 for removal.
If “NO” is the answer to any of the above questions,
please check electrical outlet, fuse and/ or circuit
breaker. If they are functioning properly, CONTACT
YOUR NEAREST ELECTROLUX AUTHORIZED
SERVICER.
A microwave oven should never be serviced by a
do-it-yourself” repair person.
* The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method
is widely recognized.
** Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is
less.
In compliance with standards set by:
FCC - Federal Communications Commission Authorized.
DHHS -
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
NOTES
1. If time appearing in the display is counting down
very rapidly, check Demonstration Mode on page 25
and cancel.
2. If the oven is set for 40 minutes and over at 80,
90 or 100 percent power level, after the rst 40
minutes the power level will automatically adjust
itself to 70 percent power to avoid overcooking.
U&C 2.0 side control_UL [B320] [28 28U&C 2.0 side control_UL [B320] [28 28 2/3/12 4:54:36 PM2/3/12 4:54:36 PM
Loading ...