PERFORMANCE DATA SHEETS
Water Filtration System
Model UKF8001AXX-200/UKF8001 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53 and 401 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specied in NSF/ANSI Standards 42, 53, and 401.
Substance Reduction
Aesthetic Effects
Inuent Challenge Concentration Maximum Permissable
Product Water Concentration
Average% Reduction
Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 97.6%
Particulate Class I* At least 10,000 particles/mL 85% reduction 98.8%
Contaminant Reduction Inuent Challenge Concentration Maximum Permissable
Product Water Concentration
Average% Reduction
Lead***: @ pH 6.5 / @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L 99.3% / 99.3%
Mercury: @ pH 6.5 / @ pH 8.5 0.006 mg/L ± 10% 0.002 mg/L 95.1% / 95.0%
Asbestos 10
7
to 10
8
bers/L
††
>99% >99%
Cysts
50,000/L min. >99.95% 99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 98.1%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 94.4%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.6%
Carbofuran 0.080 mg/L ± 10% 0.040 mg/L 86.8%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 98.8%
P-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.7%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.0%
Toxaphene 0.015 mg/L ± 10% 0.003 mg/L 93.8%
Atenolol 200 ± 20% 30 ng/L >95.9%
Endrin 0.006 mg/L± 10% 0.002 mg/L 96.7%
Ethylbenzene 2.1 mg/L ± 10% 0.7 mg/L 99.9%
o-Dichlorobenzene 1.8 mg/L± 10% 0.6 mg/L 99.9%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 97%
Carbamazepine 1400 ± 20% 200 ng/L >98.6%
DEET 1400 ± 20% 200 ng/L >98.5%
Linuron 140 ± 20% 20 ng/L >96.8%
Meprobamate 400 ± 20% 60 ng/L 94.6%
Metolachor 1400 ± 20% 200 ng/L 98.3%
Trimethoprim 140 ± 20% 20 ng/L >96.4%
Bisphenol A 2000 ± 20% 300 ng/L 99.4%
Estrone 140 ± 20% 20 ng/L >96.7%
Nonylphenol 1400 ± 20% 200 ng/L >98.9%
Ibuprofen 400 ± 20% 60 ng/L 92.9%
Naproxen 140 ± 20% 20 ng/L >96.3%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certied under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
It is important that operational, maintenance, and lter replacement
requirements be carried out for the product to perform as advertised. Property
damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement lter UKF8001, Part #EDR4RX D1/EDR4RXD1B. 2015
suggested retail price of $49.99 U.S.A./$49.95 Canada. Prices are subject to
change without notice.
The lter monitor system measures the amount of water that passes through the
lter and alerts you when it is time to replace the lter. To learn how to check
the water lter status, see “Using the Controls” or “Water Filtration System” in
the User Instructions or User Guide.
After changing the water lter, ush the water system. See “Water and Ice
Dispensers” or “Water Dispenser” in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing was
performed under standard laboratory conditions, actual performance may vary.
System tested and certied by NSF International against NSF/ANSI
Standard 42, Standard 53, and Standard 401 for the reduction of
contaminants specied on the Performance Data Sheet.