Connection in Ducting Version
When installing the ducting version, connect the
hood to the chimney using either a exible or rigid
pipe ø 150 or 120 mm, the choice of which is left to
the installer.
qTo install a ø 120 mm air exhaust connection,
insert the reducer ange 9 on the hood body
outlet.
qFix the pipe in position using sufcient pipe
clamps (not supplied).
qRemove charcoal lters, if present.
Installation
Connection in Recirculation Version
All the items named in this procedure are
included in the recirculation kit. The correspond-
ing accessory numbers can be found at the end
of these operating instructions.
qPut connection 15 into the connection support
7.3.
qInsert the connection extension pieces laterally
14.1 in connection 15.
qMake sure that the outlet of the extension
pieces 14.1 is horizontally and vertically aligned
with the chimney outlets.
qConnect the air outlet connection 15 to the
hood body outlet using either a pipe ø 150 mm.
qUse the jubilee clips 25 to ensure a x connec-
tion between pipe and hood outlet and between
pipe and connection (15).
qEnsure that the activated charcoal lters have
been inserted.(see parag. “Activated carbon
lter” in Filters and Maintenance chapter)