Now Start...
With dryer in laundry area.
Electric Dryer
Electrical
requirements
If codes permit and a separate
ground wire is used, it is
recommended that a qualified
electrician determine that the ground
path is adequate
.
Important: Observe all governing
codes and ordinances.
A four-wire or three-wire, single-
phase, 120/240-volt, 60-Hz, AC-only
electrical supply (or four-wire or three-
wire, 120/208-volt, if specified on the
model/serial rating plate) is required
on a separate, 30-ampere circuit,
fused on both sides of the line. A time-
delay fuse or circuit breaker is
recommended.
Recommended
ground method
In U.S.:
It is the personal responsibility and
obligation of the customer to contact
a qualified electrician to assure that
the electrical installation is adequate
and in conformance with the
National Electrical Code, ANSI/NFPA
70*, and all local codes and
ordinances.
Copies of the standards listed above may
be obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Excessive Weight Hazard
Use two or more people to move and
install dryer.
Failure to do so can result in back or
other injury.
WARNING
1. Put on safety glasses and gloves.
Check that each leg is approximately
2.5 cm (1 inch) from base.
2. Wipe the interior of the drums
thoroughly with a damp cloth.
3. Install coin vaults and locks (not
supplied) into meter case openings.
4. Install control panel lock and
key (not supplied).
6. Secure coin slide mechanism
from inside the control panel using
the 3/16" bolt and washer included
with the slide mechanism. Install coin
box.
7. Repeat Steps 5 and 6 for the
other coin slide mechanism. Close
control panel.
5. Open control panel. Insert the
coin-slide mechanism through the
opening to left of the control panel.
GROUNDING INSTRUCTIONS:
• For a grounded, cord-connected
dryer:
This dryer must be grounded. In the
event of malfunction or breakdown,
grounding will reduce the risk of
electric shock or breakdown;
grounding will reduce the risk of
electric shock by providing a path
of least resistance for electric
current. This dryer uses a cord
having an equipment-grounding
conductor and a grounding plug.
The plug must be plugged into an
appropriate outlet that is properly
installed and grounded in
accordance with all local codes
and ordinances.
• For a permanently connected
dryer:
This dryer must be connected to a
grounded metal, permanent-wiring
system, or an equipment-grounding
conductor must be run with the
circuit conductors and connected
to the equipment-grounding
terminal or lead on the dryer.
WARNING: Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
service representative or personnel if
you are in doubt as to whether the
dryer is properly grounded. Do not
modify the plug on the power supply
cord: if it will not fit the outlet, have a
proper outlet installed by a qualified
electrician.
SAVE THESE INSTRUCTIONS
This dryer is manufactured with the
cabinet-ground conductor
connected to the NEUTRAL (center) of
the wiring harness at the terminal
block. If local codes do NOT permit
this type of connection, use “Four-
wire connection” instructions.
8.Make electrical connection.