13GAS SPECIFICATIONS
GAS SPECIFICATIONS
Turn down adjustment
When converting to natural gas the turndown setting will
need to be adjusted to give a satisfactory flame on
low setting.
Remove knobs from valve shafts.
Using a flat bladed screwdriver, turndown adjustment
screw should be fully inserted and then rotated ¾ turn
counter clockwise.
Repeat for other valve.
Following of the gas and leak testing as per previous
steps, light both burners and set to high.
One burner at a time turn the valve shaft to lowest
setting, observe the flame to ensure a small steady
flame in achieved.
Turn off burners and replace control knobs, ensuring the
knob is in the correct orientation when valve is in “OFF”
position.
Choosing a location
The vertical clearance above the cooking surface to any
combustible materials must be at least 1000mm.
Cooking with roasting hood closed vents the hot
flue gases out the rear of the appliance. A minimum
clearance of 450mm to any combustible materials is
required. This clearance should also be maintained for
brittle materials which may be affected, such as glass.
Avoid windy conditions as this will affect cooking
performance and burner efficiency. If this situation
cannot be avoided some shielding may be necessary.
This appliance must be installed in accordance with
Australian Standards AS4557 and AS5601 and in
accordance with the local authority.
Ensure there is sufficient clearance behind barbecue for
hood to open fully.
Low Flame
Control Screw