INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
kW
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Rapid
Semi-rapid
Auxiliary
115 Y
95 Z
72 X
3,00
1,65
1,00
286 l/h
157 l/h
95 l/h
0,75
0,40
0,40
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid
Semi-rapid
Auxiliary
86
63
50
3,00
1,65
1,00
218 g/h
120 g/h
73 g/h
0,75
0,40
0,40
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid
Semi-rapid
Auxiliary
86
63
50
3,00
1,65
1,00
214 g/h
118 g/h
71 g/h
0,75
0,40
0,40
25 37 45
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m3) for
burning 1m3 of gas
G20 20 mbar 1R - 2SR - 1AUX 7, 30 695 l/h 9,52
G30 28-30 mbar 1R - 2SR - 1AUX 7, 30 531 g/h 30,94
G31 37 mbar 1R - 2SR - 1AUX 7, 30 521 g/h 23,80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6W