Loading ...
Loading ...
Loading ...
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
kW
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Rapid
Semi-rapid
Auxiliary
115 Y
95 Z
72 X
3,00
1,65
1,00
286 l/h
157 l/h
95 l/h
0,75
0,40
0,40
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid
Semi-rapid
Auxiliary
86
63
50
3,00
1,65
1,00
218 g/h
120 g/h
73 g/h
0,75
0,40
0,40
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid
Semi-rapid
Auxiliary
86
63
50
3,00
1,65
1,00
214 g/h
118 g/h
71 g/h
0,75
0,40
0,40
25 37 45
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m3) for
burning 1m3 of gas
G20 20 mbar 1R - 2SR - 1AUX 7, 30 695 l/h 9,52
G30 28-30 mbar 1R - 2SR - 1AUX 7, 30 531 g/h 30,94
G31 37 mbar 1R - 2SR - 1AUX 7, 30 521 g/h 23,80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6W