10
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
Remove the Air Conditioner From the Case
Remove and discard the 2 shipping screws
from the bottom rear of the case.
Pull to unlatch the lower corners of the inlet
grille and lift it up and off.
Using the tab, pull up slightly on the filter
to release it and pull it down to remove.
Remove the two grille frame screws.
Grasp the lower corners of the grille frame
while pressing in on the case sides with your
finger tips. Pull out to release and lift it up.
NOTE: Do not pull the
bottom edge toward
you more than 3 or
you may damage the
tabs of the grille.
On some models, you must also disconnect
the control connectors before the grille frame
can be removed. Press the locking tabs in
while pulling on the other side to release.
Remove the locking screw and locking bracket
from the lower front of the unit.
Remove the screw securing the ground wire
to the right side face of the unit.
Slide the air conditioner from the case by
gripping the base pan handle and pulling
forward while bracing the case.
I
H
G
F
E
D
C
B
A
3
Window installation instructions.
Screw
Ground wire
Grille frame
screws
Press in
Pull
Press in
Loading ...
Loading ...