Instructions for the installer
36
6. POSITIONING IN THE COUNTER TOP
The following operation requires building and/or carpentry work so must be
carried out by a competent tradesman.
Installation can be carried out on various materials such as masonry, metal,
solid wood or plastic laminated wood as long as they are heat resistant (T
90°C).
6.1 Fixing to the supporting structure
Create an opening with the dimensions shown in the figure in the top surface of
the counte.
A (mm) B (mm) C (mm) D (mm) E (mm) L (mm) X (mm) Y (mm)
min 110 min 460 min 750 20÷40 min 50 600 555÷560 478÷482
Carefully position the supplied insulating seal on the outer perimeter of the hole
made in the counter top as shown in the figures below, trying to make it stick on
the entire surface by applying light pressure on it with your hands. Depending on
the hob model being installed refer to the dimensions in the figure, bearing in
mind that for both models the long front side must brush against the hole. Fix the
hob to the unit using the appropriate brackets A supplied. Carefully trim the
surplus away from edge B beyond the seal.
The dimensions given in the following drawing refer from the hole to the inside of
the seal.