Maytag KFDD500ESS cooking

User Manual - Page 7

For KFDD500ESS.

PDF File Manual, 36 pages, Download pdf file

Loading ...
Loading ...
Loading ...
7
Electrical Requirements - Canada Only
Be sure that the electrical connection and wire size are adequate
and in conformance with the CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
When a 4-wire, single phase 250 V, 60 Hz., AC only electrical
supply is available, a 40 A minimum circuit protection is
required on 30" (76.2 cm) ranges, fused on both sides of the
line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a UL or CSA International
Certified Power Cord intended to be plugged into a standard
14-50R wall receptacle. Be sure the wall receptacle is within
reach of range’s final location.
Do not use an extension cord.
The wiring diagram is located on the back of the range or in
a clear plastic bag.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 — latest edition — or CAN/CGA B149 —
latest edition.
IMPORTANT: Leak testing of the range must be conducted
according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate located
behind the control panel has information on the types of gas
that can be used. If the types of gas listed do not include the
type of gas available, check with the local gas supplier.
Propane Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial/rating plate for use with a different
gas without consulting the serving gas supplier. See “Gas
Conversions” section.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
Range Rating* Specified Rating of Power
Supply Cord Kit and
Circuit Protection
120/240 Volts120/208 VoltsAmpsTemp Rating
8.8 - 16.5 kW
16.6 - 22.5 kW
7.8 - 12.5 kW
12.6 - 18.5 kW
40 or 50
50
194°F (90°C)
194°F (90°C)
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Loading ...
Loading ...
Loading ...