Location
Ubicacibn
30" min. cabinet width.
30", minimo abertura
deI gabinete
\
\
A
to floor
al piso e
I
I
NOTE:There must beat teast one wall stud within cabinet opening.
NOTA:debe haberal menos un montante de pareddentro de la
abertura detgabinete.
12" to 14" recommended
cabinet depth
12" a 14", profundidaddeI
abinete recomendada
II
I I
i I I
i_ ........ ,J i-
...... TI',
I I I
i i ]
wall studs
Montantes
depared
Product dimensions
Dimensiones del producto
16-1/4"
66" min. from floor to top of wall mounting
plate.
66"minimo desde el piso hastala parte
superior de la placade montaje en la pared.
30"min.to cookingsurface(or countertop)
belowmicrowavehood.
30"minimodesdelasuperficieparacocinar
(o encimera)debajode la campanadelhorno.
Checkthe opening where the microwave hood will be
installed.The location must provide:
v" 2"X 4" wood studding and 3/8" thickness drywall or
plaster/lath.
v" Support for weight of 150 pounds, which includes
microwave hood combination and items placedin the
oven and upper cabinet.
v" 30"wide minimum opening.
v" 12"to 14" recommendedupper cabinet depthto allow for
removal or servicing if needed.
v" Protection from draft areas,such aswindows, doors and
strong heatingvents.
v" Groundedelectrical outlet. See"Electrical Requirements,"
page6.
Revisela abertura donde se instalar9 la campanadel horno.
Ellugar debetener:
v" Montante demaderade2"x 4"y muro interior sin
mortero o yeso/list6n demaderade3/8" de espesor.
v" Soporte parael pesode la combinaci6n de la campanadel
homo de 150 libras, m_s el peso de los articulos que se
colocan dentro del homo y el gabinetesuperior.
v' Abertura minima de30" de ancho.
v" Profundidad recomendadade 12" a 14" del gabinete
superior para permitir sacar la campanao repararlao
darle servicio si fuera necesario.
v" Protecci6n contraareascon corrientes de aire,tales como
ventanas,puertas y conductos deventilaci6n deaire
caliente.
v" Tomacorriente puesto a tierra. Vet "Requisitos EI6ctricos"
en la pggina 6.
4
Electrical El ctricos
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result
in death, fire, or electrical shock.
3-prong
groundplug
enchufede puesta
a tierra de tres
terminales
/
/
powersupply
cord groundprong \
\
cable de terminal para \
alimentaeign eonexibnaUerra 3-prong ground-type
wall receptacle
tomaeorriente de
paredcon tres
terminales para puesta
aUerra
Important:Observeall governingcodesandordinances.
It isthe customer'sresponsibility:
Tocontacta qualified electrical installer.
Toassurethatthe electrical installationis adequateand
in conformancewith National ElectricalCode,ANSI/NFPA
70 -- latest edition*, and all local codesand ordinances.
Youmusthave:
v" 120-volt, 60Hz,AC-only,15- or 20-amp., fused
electricalsupply.
v" outlet located in the upper cabinet as close as
possible to the microwave hood.
We recommend:
v' a tirne-delayfuse or circuit breaker.
v" a separatecircuit servingthis applianceonly.
If codespermit and a separate groundwire is used, it is
recommendedthat a qualifiedelectrician determinethat
the groundpath isadequate.
Recommendedgroundmethod
Foryour personalsafety,this appliancemust be grounded. This appliance is equipped with
a power supply cord having a 3-prong ground plug. Tominimize possible shock hazard,the
cord must be plugged into a mating 3-prong ground-type wall outlet, grounded in
accordancewith the National ElectricalCode,ANSI/NFPA70 -- latestedition*, and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
* National FireProtection Association
BatterymarchPark
Quincy,Massachusetts02269
Peligro de choque eldctrico
EnchQfelo en un tomacorriente de pared de
conexibn a tierra con 3 terminales.
No quite el terminal para conexibn a tierra.
No use adaptador.
No use cable de extensibn.
No seguir estas instrucciones puede ocasionar
la muerte, un incendio o un choque eldctrico.
Importante:cumplacontodoslos c6digosy reglamentos
vigentes.
Esresponsabilidaddel cliente:
Llamara ont6cnicoen instalacionesel_ctricascaiificado
parahacer la instalaci6n.
Asegorarsede que la instalaci6nel_ctricasea correctay
adecuaday de acuerdoconel C6digoNacionalde Energia
ANSI/NFPA70 -- iiltima edici6n*, y todoslos c6digosy
reglamentoslocales.
Usteddebe tener:
v" Un surninistro el6ctrico,protegido por fusible, de 120
voltios, 60 Hertz,s61ode CA,de 15 6 20 amperios.
v" Untomacorriente de pared ubicadoen el gabinete
superior Io mgs cerca posible de la campana del horno.
Rec0mendam0s:
v' Unfusible de retardo oun disyuntor.
v" Uncircuito separados6lo paraesteaparatoelectrodom6stico.
Si los c6digosIo permiten y se usauncable de poesta a
tierra separado,se recomiendaqoeon electricistacaiificado
determinesi el trayectodela puestaa tierra es adecuado.
M6todorecomendadoparala puestaa tierra
Parasu seguridad personalesteartefactodebe set puesto a tierra. Esteartefacto est_
equipado con un cablede alimentaci6n provisto de un enchufe de puesta a tierra de tres
terminales. Parareducir al minimo el riesgo de choque el6ctrico, el cabledebeser
enchufado en un tomacorriente de pared del mismo tipo con tres terminales, puesto a tierra
de acuerdo con el C6digo Nacional de ElectricidadANSI/NFPA70 -- _ltima edici6n*, y
todos los c6digos y reglamentoslocales.
Copia de las normas indicadas se pueden obtener en:
* National Fire ProtectionAssociation
BatterymarchPark
Quincy,Massachusetts 02269
5