42
348248
Problem/error Cause What to do ...?
The dryer does not work. No voltage in the power
outlet
• Check if the power cord plug
is correctly inserted into the
power outlet.
• Check the fuse.
There is voltage in the
outlet, but the drum
does not spin and the
dryer does not work.
• Program was not started
in accordance with the
instructions.
• The door is not properly
closed.
• Condensate tank is full.
• Delayed start function has
been selected.
• Reread the instructions for use
again.
• Push the door towards the
appliance.
• Empty the condensate tank
(see section Cleaning and
Maintenance).
• Wait until the time indicated on
the display elapses.
Laundry is not dried, or
drying temperature is
longer than 4h.
• Filters are not clean. The
room is not sufficiently
ventilated.
• Inappropriate temperature
in the room
• Laundry was not sufficiently
wrung or spun.
• Amount of laundry dried in
the appliance is too large or
insufficient.
• Clean the filters.
• Install the dryer in an
appropriate room (see section
Installation ...)
• Check if the temperature in
the room where the dryer is
installed is too high (over 25°C)
or too low (below 10°C).
• Laundry inserted into the dryer
was not sufficiently wrung or
spun, or an inappropriate drying
program was selected.
• Use an appropriate program or
use the timed program. Increase
the final level of dryness for the
selected program (intensive
drying function).
Unevenly dried laundry. • The amount of laundry
dried at a time is too large.
• Drying the pieces of
different thicknesses
• Drying the different types
of laundry
• Make sure the laundry is sorted
by type and size of items given
the selected program (see
section Drying – Preparing
the Laundry and the Program
Table).
Error in the drum
lighting.
• There is no lighting when
the dryer door is opened.
• Disconnect the dryer from
the power mains and call an
authorized service unit.
On display: F3 • Full condensate tank
• If the condensate tank is
empty, there is a pump
failure.
• Empty the condensate tank
(see section Cleaning and
Maintenance).
• Disconnect the appliance and
call the nearest service unit.
On display:F4 • Clogged filters
• If the filters are clean,
there may be a compressor
failure.
• Clean the filters.
• Disconnect the appliance and
call the nearest service unit.
On display:"LO" • Steam generator tank is
empty
• Add distilled water
Write down the failure/error code: F0, F1, or F2, disconnect the appliance and call the
nearest authorized service (call center).