En-11
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
Cleaning and Care (continued)
Air cleaning lter installation
1
Open the intake grille and remove the air lters.
Air lter (Right & Left)
2
Install the air cleaning lter set (set of 2).
(1) Set the air cleaning lter into the air cleaning lter frame.
Air cleaning lter
Air cleaning lter frame
(2) Engage the latch at both ends of the lter with the two hooks
at the rear of the air cleaning lter frame.
Hook (2 places at the rear)
Latch (2 places)
Take care that the air cleaning lter does not project beyond the
frame.
(3) Engage the six xing locations at the top and bottom of the air
cleaning lter frame with the hooks of the air lter.
Rear of the lter
Fixing location,
hook (6 places)
3
Install the two air lters and close the intake grille.
• When air cleaning lters are used, the effect will increased by
setting the fan speed to “HIGH”.
Replacing dirty air cleaning lters
Replace lters with the following components (purchased separately).
• APPLE-CATECHIN FILTER: UTR-FA13-1
• ION DEODORIZATION FILTER: UTR-FA13-2
1
Open the intake grille and remove the air lters.
2
Replace them by two new air cleaning lters.
(1) Remove the old air cleaning lters in reverse order of their
installation.
(2) Install in the same way as for installation of the air cleaning
lter set.
3
Install the two air lters and close the intake grille.
[In regard to the air cleaning lters]
APPLE-CATECHIN FILTER (1 sheet)
• The lters are disposable lters. (They can not be washed and
reused.)
• For storage of the lters, use the lters as soon as possible after the
package has been opened.
(The air cleaning effect decreases when the lters are left in the
opened package)
• Generally, the lters should be exchanged about every 3 months.
Please buy dedicated APPLE-CATECHIN FILTER (UTR-FA13-1)
(Sold separately) to exchange the used dirty air cleaning lters.
ION DEODORIZATION FILTER (1 sheet) - light blue
• The lters should be exchanged about every 3 years so as to
maintain the deodorizing effect.
Please buy dedicated ION DEODORIZATION FILTER (UTR-FA13-2)
(Sold separately) when exchanging the lters.
[Maintenance of ION DEODORIZATION FILTER]
In order to maintain the deodorizing effect, please clean the lter in the
following way every 3 months.
1. Remove the lter.
2. Clean with water and dry in the air.
(1) Flush the lters with high-pressure hot water until the surface
of the lters are covered with water. Please ush with diluent
neutral detergent.
(Never wash by reaming or rubbing, otherwise it will damage
the deodorizing effect.)
(2) Rinse with water ow.
(3) Dry in shade.
3. Reinstall the lter.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
FAN operation for half a day to dry the internal parts throughly before
you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the product performance even if you have maintained the unit
with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.