When connecting to a 4-wire eJectricaJ system,
when instaJJing in a mobiJe home, or when JocaJ
codes DO NOT permit connecting the cabinet-
grounding conductor to the neutraJ (white) junction
box wire (see Figure 3)
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit breaker, fuse box or junction box:
connect appliance and residence cable wires as shown
in figure 3.
Cable from
Green Residence
(or Bare Copper)
Red_
Wires
Green
(or Bare Copper)
Wire
Junction
Box
White Wire
eutral)
I"S whitewire
Cable from Conduit
Appliance Connector
(or CSA listed)
Figure 3 - 4-Wire Electrical System
(Example: Junction Box)
Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with this appliance are UL-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than the temperature rating of household wiring.
The current carrying capacity of the conductor is
governed by the temperature rating of the insulation
around the wire, rather than the wire gauge alone.
Range Installation
The electrical power to the range
must be shut off while line connections are being
made. Failure to do so could result in serious injury
or death.
Countertop Preparation
* The cooktop sides of the range fit over the cutout edge
of your countertop.
* If you have a square finish (flat) countertop, no
countertop preparation is required. Cooktop sides lay
directly on edge of countertop.
, Formed front-edged countertops must have molded
edge shaved flat 3/4" (1.9 cm) from each front corner
of opening (Figure 4).
, Tile countertops may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge
flattened (Fiqure 4).
31,/2,__
(81 cm)
Formed or tile countertop
trimmed %" (1.9 cm) back at
front corners of countertop
(1.9 cm) opening.
I Figure 4
If the existing cutout width is greater than
30 1116" (76,4 cm), reduce the 3A" (1.9 cm)
dimension.
For existing cutout width of 29" (73.7 cm) (Figure 5):
2 3/16"
2 3/16" (5.56 cm) YOU must also clear
_l (s's6 crn) 2 3/16" (5.56 cm) of
material from front
of countertop.
1v4"
(3.2 cm)
311/z"
(80 cm)
_ ._ Formed or tile countertop
11/4"
(3.2cm) _ trimmed 11A'' (3.2 cm) back at
front corners of countertop
I opening.
Figure 5