3. Use UL listed wire connectors and connect black wires (B)
together.
4. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (C) in terminal box using UL
listed wire connectors.
5. Install terminal box cover.
6. Check that all light bulbs are secure in their sockets.
7. Reconnect power.
Install Vent Covers (Optional)
If you are installing an optional full width duct cover, follow the
instructions included with that product.
Complete Installation
1. Install metal grease filters. See the “Range Hood Care”
section.
2. Check the operation of the range hood blower and light. See
the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the underside of the range
hood.
Range Hood Controls
Operating the light
1. Move the light switch to the “1” position to turn range hood
light to night light setting.
2. Move the light switch to the “2” position to turn range hood
light to full light setting.
3. Move the light switch to the “Off” position to turn range hood
light OFF.
Operating the fan
1. Move the fan switch to the “On” position to turn the fan ON.
The fan will begin operating at the speed set on the fan speed
switch.
2. Move the fan switch to the “Off” position to turn the fan OFF.
Auto On Fan
The range hood is equipped with a sensor to automatically turn
on the fan when excessive heat is detected in the control area.
When the fan switch is in the “Off” position, this sensor will turn
the fan to high speed when necessary. When the heat decreases,
the fan will turn off.
When the fan switch is in theOn position, the heat sensor is not
active and the range hood functions normally.
Adjusting the fan
The fan has 3 speed controls. Move the fan speed switch to “1”
position for low speed, “2” position for medium speed, or “3”
position for high speed.
Thermal Protector
The range hood is equipped with a thermal protector to avoid
overheating conditions. If the range hood shuts off while in use,
move fan slider switch to Off to turn off the range hood. Wait
approximately 60 minutes, then move slider to On to restart the
range hood.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A. Light control
B. Blower control
C. Fan speed control
A
B
C