GB5
DESCRIPTION AND USE OF HOOD
1. Control panel
a. Light switch.
b. Extraction and minimum extraction speed ON/OFF switch.
c. Medium extraction speed switch.
d. Maximum extraction speed switch.
2. Grease lter
3. Grease lter release handle
4. Halogen bulb
5. Steam deector
6. Telescopic ue
7. Air outlet (for lter version only)
MAINTENANCE
GREASE FILTERS.
Metal grease lters have an unlimited life and should be washed once a month either by hand or in a dishwasher at a low temperature and
with a short cycle.
Washing in a dishwasher can cause grease lters to turn white, but this in no way aects eciency.
a. press the handle to remove the lter
b. remove it.
Wash the lter and leave it to dry, proceeding in reverse order to ret it.
Halogen lamps:.
Use a small athead screwdriver or any other tool ideal for lifting away objects.
Remove the old light bulb and replace with a new one.
Lamp
Power
(W)
Socket
Voltage
(V)
Dimension
(mm)
ILCOS D Code
(according IEC 61231)
10 G4 12
10 (Diameter)
22( Light Center
Length)
HSGST/C/UB-10-
12-G4-10/22
Follow package directions and do not touch new light bulb with bare hands.
Slot back into place.
ACTIVE CARBON FILTER (lter models only):
The carbon lter must be washed once a month in a dishwasher at the highest temperature, using a normal
dishwasher detergent. Wash the lters on their own.
After washing, reactivate the carbon lter by drying it in the oven at 100° C for 10 minutes.
Change the carbon lter every 3 years.
Fitting the carbon lter:
1. Remove the grease lter.
2. Remove the lter holder by turning the knobs through 90°.
3. Fit the carbon lter “i” inside the lter holder “h”.
Reverse the above procedure to re-t the lter holder and grease lter.
a