StatusConvenience Cord LED Indicators
VehicleFaultCheck
Outlet
The convenience cord is not connected to your
vehicle.
OffOffOff
The convenience cord is connected, but your
vehicle is not charging.
OnOffOff
Your vehicle is charging.BlinkOffOff
Ground Fault Circuit Interrupter (GFCI) Fault
Detected.
OffBlinkOff
The convenience cord is retrying to charge.
Ground Fault Circuit Interrupter (GFCI) Fault
Detected.
OffOnOff
The convenience cord has exhausted its retry
attempts. Your vehicle is not charging, or there is
an internal fault in the charging equipment.
The convenience cord detected a high temper-
ature at the AC plug and is waiting for the AC plug
to return to a normal operating temperature.*
OffOffBlink
The convenience cord detected a high temper-
ature at the AC plug. The AC plug has returned to
a normal operating temperature. Your vehicle is
ready to charge at a reduced current.*
OnOffBlink
The convenience cord detected a high temper-
ature at the AC plug. The AC plug has returned to
a normal operating temperature. Your vehicle is
charging at a reduced current.*
BlinkOffBlink
The convenience cord detected a high temper-
ature at the AC plug. Your vehicle is not charging.
The convenience cord has exhausted its retry
attempts.*
OffOnBlink
*Have the outlet checked by a qualified electrician and make sure the AC plug fits firmly
into the outlet. Contact an authorized EV certified dealer if problem persists.
157
C-MAX (CCG) Canada/United States of America, enUSA, First Printing
High Voltage Battery