Installation
21
EN
3. Adjust the air flow by moving the air
regulator B to obtain the distance D
given in the relevant table (see “Burner
and nozzle characteristics table”).
4. After adjusting each burner, reassemble
the appliance correctly.
Adjusting the minimum setting for natural
gas
Light the burner and turn it to the minimum
position. Extract the gas tap knob and turn
the adjustment screw next to the tap rod
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: the
flame should not go out. Repeat the
operation on all gas taps.
Adjusting the minimum setting for LPG
Burner and nozzle characteristics table
1 ULPG 2.75 kPa AUX SR RR R1 R2
Nominal gas consumption (MJ/h)
4.1 6.0 9.4 14.5 10.8
Injector (1/100 mm)
54 67 82 100 85
Primary air (mm)
422103
2 NG 1.0 kPA AUX SR RR R1 R2
Nominal gas consumption (MJ/h)
4.7 6.1 9.4 14.5 10.8
Injector (1/100 mm)
98 110 135 170 145
Primary air (mm)
4326 5