GE AEC12AVH1 - 115 Volt Electronic Room Air Conditioner

User Manual - Page 5

For AEC12AVH1. Also, The document are for others GE - General Electric models: AEC10, AEC12, AED10

PDF File Manual, 32 pages, Read Online | Download pdf file

AEC12AVH1 photo
Loading ...
Loading ...
Loading ...
49-7770 5
Controls
Cool Mode
8VHWKH&RROPRGHDWLow, Med, High or Auto Fan
SpeedIRUFRROLQJ8VHWKHTemperature Increase
ŸDecreaseźSDGVWRVHWWKHGHVLUHGWHPSHUDWXUH
between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on and off
to keep the room at the set level of comfort. Set the
thermostat at a lower number and the indoor air will
become cooler. Set the thermostat at a higher number
and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan setting
WRD&RROVHWWLQJLWPD\WDNHDSSUR[LPDWHO\PLQXWHVIRU
the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and High
or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and
High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the Cool
mode and Low fan with a middle set temperature.
Energy Saver Mode
This mode optimizes the cooling power of your air
conditioner, thereby saving you energy. Once the set
point temperature has been reached, the fan will cycle
off to save energy. The fan will cycle back on periodically
to insure all cooling capacity in the system is used. This
mode is the default mode for the unit. Each time the
unit is powered off, it will restart in Energy Saver mode
ON. The first time the unit is turned on, the settings will
be 70° and Low fan. You can adjust the fan speed and
temperature to your personal comfort.
Energy Saver ON—Helps minimize electricity use. It
is normal for the fan to cycle off and then back on in
this mode. This on/off cycle can repeat multiple times.
Because the fan will cycle off, you may notice a variation
in room temperature and humidity.
Energy Saver OFF—When this mode is not engaged,
the fan will run continuously, and in Cool mode the
compressor will cycle on and off to maintain room
temperature.
Fan Only Mode
8VHWKH)DQ2QO\0RGHDW/RZ0HGRU+LJKIDQVSHHG
to provide air circulation and filtering without cooling.
Since fan-only settings do not provide cooling, a Set
temperature cannot be entered. The room temperature
will appear in the display.
NOTE: Auto Fan Speed cannot be used when in the Fan
Only Mode.
Auto Fan Speed
Set to Auto fan speed for the fan speed to automatically
set to the speed needed to provide optimum comfort
settings with the set temperature.
If the room needs more cooling, the fan speed will
automatically increase. If the room needs less cooling,
the fan speed will automatically decrease.
NOTE: Auto Fan Speed cannot be used when in the Fan
Only Mode.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will
automatically restart in the settings last used after the
power is restored.
Air Direction
8VHWKHOHYHUWRDGMXVWWKHDLUGLUHFWLRQOHIWDQGULJKW
only.
OPERATING INSTRUCTIONS
Loading ...
Loading ...
Loading ...