USER MANUAL 8,000 BTU Window-Mounted Room Air Conditioner

Air Conditioner Features & Operating Instructions

Air Conditioner Features

ELECTRONIC CONTROL

  • Before you begin, thoroughly familiarize yourself with the control panel and remote as shown below and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the touch pad alone or with the remote.

Light Feature:

  • The display and all LED indicators on the control panel of the unit can be turned off by pressing the "Light" button on the remote control. If any other button of the control panel and remote control is pressed after that, the unit will beep to indicate it works as the corresponding direction of pressing specific button, and the display and LED indicators will illuminate accordingly, but they will turn off again in 5 seconds if no further operation.
  • Press the "Light" button again or unplug the unit to cancel this setting.

Battery Size: AAA

Warning: Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.

Operating Instructions

TO TURN UNIT ON:

YOU WILL SEE:

NOTE: The unit will run in Cool mode with Eco feature and Auto fan speed setting when used for the first time. With the Eco feature, when the room temperature is below the set temperature, the fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on. Eco feature can be activated or deactivated by pressing Eco button, but it is invalid in fan only mode.

AUTO FEATURE:

YOU WILL SEE:

Note: This mode is a fixed combination of Cool mode and Auto fan speed setting. In this mode, the fan speed can not be selected manually

COOL FEATURE:

YOU WILL SEE:

Note: In this mode, the fan remains on all the time with the compressor cycling on and off when room temperature is reached.

TO CHANGE TEMPERATURE SETTlNG:

YOU WILL SEE:

Note: Tap or hold either up ( ) or down ( ) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62 °F (17 °C) and 86 °F (30 °C). If you want the display to read the actual room temperature.

TO ADJUST FAN SPEEDS:

YOU WILL SEE:

Note: The fan speed can be selected among four settings: Auto, Lo(Low), Med(Medium) and Hi(High), unless the unit runs in "Auto" or "Dry" mode, or the Sleep feature is activated.

TO USE AUTO FAN FEATURE:

YOU WILL SEE:

Note: Fan starts at Low Speed and adjusts to a proper speed according to the room temperature dictates. For example, if the room doesn't get too warm, it will stay at the slowest speed. If the room temperature rises quickly, such as a door being opened, it will automatically go to the highest speed. The fan speeds will re-adjust back to the slowest speed as the room returns to the original set temperature.

TO OPERATE ON FAN ONLY:

YOU WILL SEE:

Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air on some models. (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.

During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.

DRY MODE:

YOU WILL SEE:

Note: In this mode, the air conditioner will work like a dehumidifier, but it will cool the room down meanwhile. The temperature can be adjusted between 62 °F (17 °C) and 86 °F (30 °C) and fan speed will be held at “Lo”.

SLEEP FEATURE:

YOU WILL SEE:

Note: In this mode, the unit will select Auto fan speed automatically, and the selected temperature will increase by 2 °F 30 minutes after the mode is selected. The temperature will then increase by another 2 °F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the "Sleep" mode and the unit will continue to operate as originally programmed. The "Sleep" mode program can be cancelled at any time during operation by again pressing the "Sleep", “Fan speed” or “Mode” button.

CHECK FILTER FEATURE, YOU WILL SEE:

Note: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Filter Reset" button and the light will go off.

Care and Cleaning & Energy Saving Ideas

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.

  • Push the vent handle to the Vent Closed position(where applicable).
  • Open the front panel.
  • Grasp the filter by the center and pull up and out.
  • Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing
  • Or instead of washing, you may vacuum the filter clean.

NOTE: When replacing the air filter after cleaning, make sure the tabs on the air filter are on the upper part of filter, and placed outward as shown in the drawing on the left side

Cabinet Cleaning

  • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
  • Never use harsh cleaners, wax or polish on the cabinet front.
  • Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.
  • Plug in air conditioner.

Winter Storage

  • If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.

Energy Saving Ideas

  • Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs, enclosures, or other buildings.
  • The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation.
  • Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day.
  • Close the fireplace damper, floor and wall registers so cool air does not escape up the chimney and into the duct work.
  • Keep blinds and drapes in other windows closed during the sunniest part of the day
  • Clean the air filter as recommended in the section “Care and Cleaning”.
  • Proper insulation and weather stripping in your home will help keep warm air out and cool air in.
  • External house shading with trees, plants or awnings will help reduce the air conditioner’s work load.
  • Operate heat producing appliances such as ranges, washers, dryers and dishwashers during the coolest part of the day

Before You Call

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

Air conditioner will not operate

  • Wall plug disconnected. Push plug firmly into wall outlet.
  • Plug Current Device Tripped. Press the RESET button.
  • House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
  • Control is OFF. Turn Control ON and set to desired setting

Air from unit does not feel cold enough.

  • Room temperature below 62°F (17°C). Cooling may not occur until room temperature rises above 62°F (17°C).
  • Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.
  • Reset to a lower temperature
  • Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode.

Air conditioner cooling, but room is too warm - ice forming on cooling coil behind decorative front

  • Outdoor temperature below 62 F (17 C). To defrost the coil, set FAN ONLY mode. O O
  • Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode
  • Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, set temperature to a higher setting.

Air conditioner cooling, but room is too warm - NO ice forming on cooling coil behind decorative front.

  • Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
  • Temperature is set too high. Set temperature to a lower setting.
  • Air directional louvers positioned improperly. Position louvers for better air distribution.
  • Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.
  • Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
  • Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and furniture.

Air conditioner turns on and off rapidly.

  • Dirty air filter - air restricted. Clean air filter.
  • Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils more frequently.

Noise when unit is cooling.

  • Air movement sound. This is normal. If too loud, set to lower FAN setting.
  • Window vibration - poor installation. Refer to installation instructions or check with installer.

Water dripping INSIDE when unit is cooling.

  • Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions or check with installer

Water dripping OUTSIDE when unit is cooling.

  • Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.

Remote Sensing Deactivating Prematurely (some models).

  • Remote control not located within range. Place remote control within 20 feet & 120° radius of the front of the unit.
  • Remote control signal obstructed. Remove obstruction.

Room too cold.

  • Set temperature too low. lncrease set temperature.
  • Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote control or deactivate remote sensing.


See other models: FMV145BC FCRG3052AB FFRA0622S1 FGEF3058RB FGGH3047VF

Frigidaire FFRE063WAE | File type: PDF | Filename: 17379334_ffra082wa1.pdf | Size: 1.31 MB | Language: English | Other documents: 4 files.

Download User Manual

Product Infomation and Reviews - FFRE063WAE photo

FFRE063WAE Photo

Frigidaire in United States

1-800-374-4432 Mon-Fri, 8:30am - 8pm (EST)

Frigidaire FFRE063WAE Questions and Answers

Find answers or Ask a question.
  • Total questions: 2
  • Questions unAnswered : 2

#1 What are this air conditioners dimensions?
Width 18-1/2"
Cabinet Depth (w/ Front) 15-1/2"
Cabinet Height 13-7/32"
Cabinet Depth 15-1/2"
Cabinet Depth (w/ Front) 15-1/2"

#2 Does it cause condensation on windows or dampness in
the room? Also, confirming, the electrical cord is on the left
of the unit, correct?
An air conditioner acts like a dehumidifier, if installed
correctly the moisture drains outside in the rear. If the
unit is too large for the room you might have some
moisture problems because the room will reach
temperature before the humidity is all remove from the
air. Yes the cord is on the left when looking at it.

#3 Can i mount it to the wall if i have a whole cut out?
The one I have has vents along the sides of it to allow
air into the unit. If the wall was say 6" thick it would
block nearly the entire side vent, if the wall was say 4"
thick it would block approximately half the vents
lengthwise. I think you would have a problem with the
unit unless the vents are open to the air.