2. Remove terminal block cover
Before you start, disconnect power. Remove hold-down
screw (B) and terminal block cover (C).
B
C
A
D
A. Center terminal block screw
B. Hold-down screw
C. Terminal block cover
D. External ground conductor screw
Electrical Connection, 24" (61 cm) 240V Electric Models
(U.S.A. Only)
Power Supply Cord
Electrical Connection Options
1. Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to “4-Wire
Power Supply Cord Connection.”
Then, go to “Venting Requirements.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Go to “3-Wire
Power Supply Cord Connection.”
Then go to “Venting Requirements.
NOTE: If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-Wire Connection.”