PROBLEM POSSIBLE CAUSE
REFRIGERATOR May be in defrost cycle when compressor does not operate for about
DOES NOT OPERATE 30 minutes.
Temperature control in the OFF position.
If interior light is not on, refrigerator may not be plugged in at wall outlet.
The fuse is blown/circuit breaker is tripped. Replace fuse or reset
the breaker.
MOTOR OPERATES Normal when refrigerator is first plugged in. Wait 24 hours for the
FOR LONG PERIODS refrigerator to completely cool down.
OR CYCLES ON AND
The new variable speed compressor is designed to run for longer
OFF FREQUENTLY
periods of time to optimize efficiency and noise. You may notice the
compressor and/or fan speeds accelerate based upon door openings
and/or increased food loads.
You may hear the fans spinning at high speeds. This happens when
the refrigerator is first plugged in, when the doors are opened
frequently or when a large amount of food is added to the
refrigerator or freezer compartments. The fans are helping to
maintain the correct temperatures.
Door left open or package holding door open.
If either door is open for over 3 minutes, you may hear the fans
come on in order to cool the light.
Hot weather or frequent door openings. This is normal.
Temperature controls set at the coldest setting. See Temperature Controls.
OPERATING Refrigerator is so quiet, that most of the time you will hear low or no
SOUNDS operating noise.
Normal fan air flow—one fan blows cold air through the fresh food
and freezer compartments—another fan cools the compressor motor.
The fans change speeds in order to provide optimal cooling and
energy savings.
These NORMAL sounds will also be heard from time to time:
– You may hear a whooshing or gurgling sound when the doors close.
This is due to pressure equalizing within the refrigerator.
– A water dripping noise may occur during the defrost cycle as ice
melts from the evaporator and flows into the drain pan.
– The flow of refrigerant through the freezer cooling coils may make
a gurgling noise like boiling water.
– Water dropping on the defrost heater can cause a sizzling, popping
or buzzing sound during the defrost cycle.
– You may hear cracking or popping sounds when the refrigerator is
first plugged in or during/after the defrost cycle. This happens as the
refrigerator cools to the correct temperature.
– Electronic dampers click open and closed to provide optimal cooling
and energy savings.
– The compressor may cause a clicking or chirping sound when
attempting to restart (this could take up to 5 minutes).
– The electronic control board may cause a clicking sound when
relays activate to control refrigerator components.
– Ice cubes dropping into the bin and water running in pipes
as icemaker refills.
– The icemaker water valve will buzz when the icemaker fills
with water.
DOOR NOT CLOSING Package holding door open.
PROPERLY
Check the door gasket; it may be out of position.
Refrigerator not level. See Installation Instructions.
15