En-20
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
Where sulfi de gas is generated such as hot spring, sewage, waste water.
Where oil is splashed or where the area is lled with oily smoke (such as cooking areas
and factories, in which the properties of plastic could be changed and damaged).
Where there is high-frequency or wireless equipment.
Where the air from the outdoor unit air outlet is blocked.
Where the operation sound or air from the outdoor unit bothers the house next door.
The mounting height of indoor unit 1.8 m to 2.3 m is recommended. If it is
impossible, please consult your dealer.
Do not operate the air conditioner during interior construction and nishing
work, or while waxing the oor. Before operating the air conditioner, ventilate
the room well after such work is performed. Otherwise, it may cause volatile
elements to adhere inside the air conditioner, resulting in water leakage or
scattering of dew.
Do not use the Wi-Fi interface nearby the medical electrical equipment or peo-
ple who have a medical device such as a cardiac pacemaker or an implantable
cardioverter-defi brillator.
It can cause an accident due to malfunctions of the medical equipment or
device.
This equipment should be installed and operated with a minimum distance of
20 cm between the device and the user or bystanders.
Do not use the Wi-Fi interface nearby other wireless devices, microwaves,
cordless phones, or facsimiles.
It can cause malfunctions.
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
INSTALLATION PLACE AND
ELECTRICAL WORK
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
wall, etc.
Inverter-type
uorescent lamp
Keep a space
to prevent
the picture
distortion or
the noise.
1 m
or
more
Radio
100 mm or
more
TV
Cordless
phone or
Portable
phone
3 m or more
1 m
or more
The installation location of the outdoor
unit should be at least 3 m away from
the antennas for TV sets, radios, etc. In
areas where the reception is weak, pro-
vide greater space between the outdoor
unit and the antenna of the affected
device if operation of the air conditioner
interferes with radio or TV reception.
(25, 35, 50VG/50HZ, 60)
200/500 mm or more
For the optimum ef-
ciency and to extend
the life time of using,
the outdoor unit
should be installed in
a well-ventilated dry
place.
SPECIFICATIONS
DB: Dry Bulb
WB: Wet Bulb
Indoor Outdoor
Cooling
Upper limit
32°C DB
23°C WB
46°C DB
Lower limit
21°C DB
15°C WB
-10°C DB
Heating
Upper limit
27°C DB
24°C DB
18°C WB
Lower limit
20°C DB
-15°C DB
-16°C WB
Guaranteed operating range
Wi-Fi interface
Model MAC-568IFB-E
Input Voltage DC12.7 V (from indoor unit)
Power consumption MAX. 2 W
Size H×W×D (mm) 79×44×18.5
Weight (g) 60 (including cable)
Transmitter power level (MAX.) 17.5 dBm @IEEE 802.11b
RF channel 1ch ~ 13ch (2412~2472 MHz)
Radio protocol IEEE 802.11b/g/n (20)
Encryption AES
Authentication WPA2-PSK
Software Ver XX.00
Wi-Fi interface setting information
Indoor unit model name
Indoor unit serial number
Outdoor unit model name
Outdoor unit serial number
Wi-Fi interface MAC address (MAC)
Wi-Fi interface serial number (ID)
Wi-Fi interface PIN (PIN)
Wi-Fi interface SSID (SSID)
Wi-Fi interface KEY (KEY)
System commissioning date
Wi-Fi interface installation date
Installer contact details
Name
Telephone number
Loading ...