INSTALLATION INSTRUCTIONS HOW TO USE
Installation test (Duct check) (cont.)

Avoid long runs or runs with multiple elbows or
bends.
• Check the error code before you call for service

If the FLOW SENSE
TM
LED is turned on, check the exhaust
system for restrictions and damage. Repair or replace the
exhaust system as needed.
When the dryer is rst installed, this test should be performed to
alert you to any existing problems with the exhaust duct in your
home. However, since the test performed during normal
operation provides more accurate information on the condition
of the exhaust duct than does the installation test, the
FLOW SENSE
TM
LED during the two tests may not be the same.
Do not interrupt the test cycle, as this could result in the wrong
results.
Even if the FLOW SENSE
TM
LED is not turned on, during the test
cycle, some restrictions may still be present in the exhaust system.
Refer to the  section of this manual for
complete exhaust system and venting requirements.
Error Code Possible Causes Solutions

or

Temperature sensor failure
Turn o the dryer and call for
service.
HS
Humidity sensor failure.
Turn o the dryer and call for
service.

or

or

Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
Check the power supply or the
connection of power cord to the
terminal block. Refer to the
 section of
this manual for complete instructions.
Reset circuit breaker or replace fuse.
Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualied
electrician.
NOTE
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
Crushed or
damaged
exhaust
Lint
buildup or
blockage