SERVICING
Always disconnect the appliance from the
electricity main before proceeding with any
servicing operation.
8) REPLACING THE ELECTRICAL
COMPONENTS
For access to the various parts, remove the hotplate
from the top of the cabinet. Then overturn it, unscrew
screw “Z” and remove under part. (see fig. 9).
After these actions is possible to work on the
plates, commutators, clamps and input cable.
N.B. In case of substitution of the input cable,
the installer must keep the “earth” conductor
longer than “live” ones, and must respect the
cautions in paragraph “Electrical connection”.
To reassemble the appliance repeat the inverse
process.
9) TECHNICAL CHARACTERISTICS OF
THE ELECTRICAL COMPONENTS
To facilitate the job of the installer we present a
scheme with the characteristics of the components.
POWER OF ELECTRICAL COMPONENTS DENOMINATIONS W
TYPE AND SECTION OF THE POWER CABLES
(*) keeping in mind the contemporaneousness factor
34
Normal plate 7 positions with the protector 1000 14,5 198,4
Normal plate 7 positions with the protector 1500 18,0 198,8
Rapide plate 7 positions 1500 14,5 198,1
Rapide plate 7 positions 2000 18,0 197,0
Denomination
ECelectriccooking**
(Wh/kg)
*
*
EC
electriccooking:
Enegetic consumption calculated per kg in accordance with Regulation (EU) 66/2014.
Power
W
(cm)
Ø
Cable Type
Alimentation
single phase
230 V~
220 V~
220-240 V~
230-240 V~
Alimentation
three phasée
400 V 3N~
380 V 3N~
380-415 V 3N~
400-415 V 3N~
Alimentation
bi
phase
400 V 2N~
380 V 2N~
380-415 V 2N~
400-415 V 2N~
H05 RR-F
3 X 2.5 mm
2
(*)
5 X1.5 mm
2
(*)
4 X1.5 mm
2
(*)
H05 RN-F
3 X 2.5 mm
2
(*)
H07 RN-F
3 X 2.5 mm
2
(*)
Loading ...
Loading ...