Height dimensions are shown with the leveling legs
extended to the minimum height.
NOTE: When leveling legs are fully extended, add 5/8”
(1.6 cm) to the height dimensions. See “Product
Dimensions”.
If the floor of the opening is not level with the kitchen
floor, shim the opening to make it level with the kitchen
floor.
Location Requirements
4
INSTALLATION INSTRUCTIONS
To ensure proper ventilation for your Refrigerator, allow for a
1/4” (6.35 mm) space on each side and at the top. When
installing your Refrigerator next to a fixed wall, leave 2.1/2”
(6.35 cm) minimum clearance on the hinge side to allow for
the door to swing open.
NOTE: It is recommended that you do not install the
Refrigerator near an oven, radiator, or other heat source.
Do not install in a location where the temperature will fall
below 55 °F (13 °C). For best performance, do not block
the base grille.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire or electrical shock.
Opening Dimensions
1/4” (6.35 mm)
2.1/2” (6.35 cm)
14.3/4”
(37.5 cm)
A
1/2”
(1.3 cm)
24”
(60.96 cm) min.
B
24” (60.96 cm) min.
34.3/8” (87.3 cm) min.
35” (88.9 cm) max.
Electrical Requirements
Before you move your Refrigerator into its final location,
it is important to make sure you have the proper electrical
connection.
A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused,
grounded electrical supply is required. It is recommended
that a separate circuit serving only your Refrigerator be
provided. Use an outlet that cannot be turned off by a
switch. Do not use an extension cord.
NOTE: Before performing any type of installation, or
cleaning, unplug Refrigerator or disconnect power.
Recommended grounding method
Explosion Hazard
Keep flammable materials and vapors such as
gasoline away from Refrigerator.
Failure to do so can result in death, explosion,
or fire.
Critical dimensions:
A. 14.3/4” (37.5 cm) utility opening
B. 24” (60.96 cm) minimum opening width