15
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease lters frequently
according to the following instructions. Replace grease lters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool
or soap-lled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filter
To Remove Metal Grease Filters:
1. Use 2 hands to remove the metal grease lters. Grasp lter
handles, push toward the rear of the range hood and pull
down on the front handle to remove.
2. Repeat for each grease lter.
3. Wash metal grease lters as needed in a dishwasher or hand
wash in a hot detergent solution to clean.
To Reinstall Metal Grease Filters:
1. Grasp lter handles and place rear of lter into rear track.
2. Push down on the rear handle and set the front of the grease
lter into the front track to secure.
3. Repeat for each lter.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new lamp, do not
touch lamp with bare ngers. Replace lamp, using tissue or
wearing cotton gloves to handle lamp.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a at-blade screwdriver and gently pry the light cover
loose.
3. Remove the lamp and replace with a 120 V, 40 watt
maximum, halogen lamp made for a G-9 base.
4. Replace the light cover.
5. Reconnect power.