Rheem N/G 27Ltr Continuous Flow 60°C Hot Water System 874627NF

User Manual - Page 25

For 874627NF.

PDF File Manual, 80 pages, Download pdf file

Loading ...
Loading ...
Loading ...
TEMPERATURE CONTROL DELUXE
25
TEMPERATURE SETTINGS DELUXE CONTROLLERS
The temperature settings of each type of Deluxe controller are:
Bathroom1 & 2 Deluxe 37°C to 48°C* (in 1°C increments), 50°C
Kitchen Deluxe 37°C to 48°C* (in 1°C increments), 50°C**, 55°C, 60°C
* limited to 48°C when set to Bath Fill mode on 874 and 876 series model.
** limited to 50°C on an 876 series model.
Temperature settings
37
38
39
40
41
42
43
44
45
46
47
48
50
55
60
warm
average hot shower
hot
very hot
The installation of a Bathroom Deluxe controller(s) only (i.e. no Kitchen Deluxe controller) limits the
temperature setting of the water heater to a maximum of:
874 series 50°C
876 series 50°C
regardless of the preset outlet temperature setting of the water heater.
The installation of a Kitchen Deluxe controller will allow a maximum temperature setting of:
874 series 60°C
876 series 50°C
regardless of the preset outlet temperature setting of the water heater.
If Deluxe or standard controllers are not installed, the water heater defaults to the preset outlet temperature
setting. This may be up to:
874 series 75°C
876 series 50°C
Refer to “How Hot Should The Water Be?” on page 5.
On a building fitted with a temperature limiting device such as a tempering valve and where an 874 series
water heater is installed without a separate untempered hot water line to the kitchen, laundry or other non-
ablution area, although the Kitchen Deluxe controller will be able to display temperatures above 50°C and
the water leaving the water heater will be at the set temperature, the maximum water temperature which can
be delivered to the hot water outlets in these locations is determined by the temperature setting of the
temperature limiting device. This is usually 50°C.
On a building fitted with a temperature limiting device set to 50°C, to enable the delivery of water
temperatures above 50°C to the kitchen, laundry or other non-ablution area, separate untempered pipe work
must be installed from the water heater to the hot water outlets in these locations.