Simple troubleshooting
Problem Cause Solution
Grinding level adjustment
is stiff.
Too many beans in the
grinding unit.
Dispensing a drink from
coffee beans. Only make any
sub sequent changes to the
grinding level in small steps.
Brewing unit cannot be
inserted.
Brewing unit is in the wrong
position.
Insert the brewing unit
according to the instructions,
see the section “Cleaning the
brewing unit”.
Brewing unit is locked. Unlock the brewing unit, see
the section “Cleaning the
brewing unit”.
Protective cover of the
brewing unit cannot be
properly attached.
Brewing unit is not locked. Lock the brewing unit, see the
section “Cleaning the brewing
unit”.
There is water under the
drip tray.
This water is condensed. Do not insert drip tray without
cover.
Display shows 12:00
Power failure or appliance
switched off at mains.
Re-enter values; do not switch
the appliance off at the mains
or select the off option in the
Clock displ. menu.
Display shows
Milk container
connected?
despite connected milk
container.
Container is outside the range
of the sensor.
Position the container at the
right edge.
Material e.g. milk carton is not
recognised.
Conrm the display request
with Yes or use the enclosed
milk container.
Display shows
“Overvoltage or
undervoltage”
Voltage too high or too low. Contact electricity or grid pro-
vider. Have the power supply
checked by an expert.
Display shows
Leave device to cool
Appliance is too hot. Switch off appliance for
30 minutes.
Display shows,
for example:
Fault: E0510
The appliance has a fault. Proceed according to the
display screen.
Display shows
Fill bean container”
although the container is
already full, or the grinder
is not grinding any beans.
Beans are not falling into the
grinding unit (beans too oily).
Gently tap the bean container.
Possibly change the type of
coffee. When the bean con-
tainer is empty, wipe it with a
dry cloth.
Display shows
Clean brewing unit
Brewing unit is soiled. Clean the brewing unit.
Too much ground coffee in the
brewing unit.
Clean the brewing unit. Do
not place more than two level
measuring spoons of ground
coffee in the drawer.
The mechanism of the
brewing unit is stiff.
Clean the brewing unit, see
the section “Care and daily
cleaning”.