SYSTEM CONFIGURATION
KEYPAD CONFIGURATION
Keypad Configuration
You can customize your unit additionally using the keypad configuration options.
To enter Keypad configuration
Connect the unit to power. Press and hold the "fan speed" and the "V
" for 5 continuous seconds, within
30 seconds of the unit being powered up.
If the unit has had power for more than 30
continuous seconds, keypad configuration cannot be made.
To scroll through the Keypad Configuration Options
Press and release the "fan speed" to select the keypad configurations.
The stored value will be displayed.
To modify configuration settings
Press and release the Setpoint " " or Setpoint " " buttons.
To exit Keypad Configuration
Keypad Configuration will end on its own 30 seconds after the last button press or when the "mode" on the
Keypad is pressed.
There are 4 configuration options
˖
1. Fahrenheit/Celsius Display Switch
:
Change between degrees Fahrenheit and Celsius on the display. An “F” indicates Fahrenheit display and
'C' indicates Celsius. Default is degrees “F”.
2. Indoor Air Temperature Sensor Biasing for Cooling mode
:
Sometimes known as an anticipator, the air temperature sensor bias is used to adjust the room air
temperature reading when in cooling mode. (Not normally required.)
3. Indoor Air Temperature Sensor Biasing for Heating mode
:
Sometimes known as an anticipator, the air temperature sensor bias is used to adjust the room air
temperature reading when in heating mode. (Not normally required.)
4. Indoor Temperature Display:
Change between showing the setpoint or desired temperature during heating and cooling modes (SP)
or displaying the actual room temperature during heating and cooling modes (AA). SP mode is the
default mode.
If SP is selected the desired setpoint temperature will be displayed during heating and
cooling modes, regardless of what the actual temperature is in the room.
If AA mode is selected, the room temperature will be displayed during heating,
cooling and fan only modes.
If the mode button has been changed to either heating or cooling modes, setpoint will be displayed
for 10 seconds. After the 10 seconds, the room temperature will again be displayed.
If the on/off button is depressed (when the unit is off ) and the last mode was either cooling or
heating mode, the setpoint will be displayed for 10 seconds before displaying room temperature.
During heating and cooling modes, if either the up or down setpoint key is depressed, the display
will show the setpoint for 10 seconds. Then the room temperature will be displayed again.
Switchover between Emergency Auto Cooling Allowed and Emergency Auto Cooling
Rejected:
Press " " or " V " to switch between the display of Emergency Auto
Cooling
Allowed and Emergency Auto Cooling Rejected.
Emergency Auto Cooling Allowed: the diode displays CA.
Emergency Auto Cooling Rejected: the diode displays
CD.
10
2010 Electrolux Home Products, Inc. All rights reserved.
V
V
V
Auto cooling operation:
o
If this function is activated and room temperature reaches 85 F while the unit is in
the "STOP" setting, the unit will automatically start in air conditioning operation and will
shut off when the room temperature reach 80
o
F.