Setting the Count Down Timer
To set the count down timer, press Menu/Enter
knob and select Set Count Down.
Follow instructions in Setting the Clock section
(page 17) to set count down hour and
minutes. Once desired count down time is
selected, press Menu/Enter knob again to set
and return to the standby menu.
Radio Check
Mode
Radio Check Mode
Allows testing of important radio functions.
Test 1- Battery Level: Confirms that battery
voltage level is between 10.8 V to 15.8 V. If in that
range, it is “PASS”. Outside of that range, either
FAIL LOW” or “FAIL HIGH” will be displayed. Press
Menu/Enter knob to advance to next test.
Note
Press Dim/Escape button to
return to CB standby mode.
If 10 seconds pass or if Enter
button pressed, unit goes to
2nd test.
Test 2- RF Power Output: Confirms 3.3 to 4 Watt
output level. Once Push-to-Talk button is pressed,
Pass or Fail will be displayed if level is outside limits.
Note
Press Dim/Escape button to
return to CB standby mode. If
10 seconds pass or if Enter button
pressed, go to 3rd test.
Note
Press Push-To-Talk within 10
seconds or unit will go to the
next test.
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/ WX/
DIM
SCAN
PA
RF POWER OUTPUT
PASS
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/ WX/
DIM
SCAN
PA
RF POWER OUTPUT
FAIL
Note
Press Dim/Escape button to
return to CB standby mode.
If 10 seconds pass or if Enter
button pressed, testing is
complete. Unit will return to
CB Standby mode.
Test 3- Antenna Mismatch Warning: Press
Push-to-Talk button to check antenna/radio for
proper matching.
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/ WX/
DIM
SCAN
PA
ANTENNA
PASS
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/ WX/
DIM
SCAN
PA
ANTENNA
FAIL
1
2
3
1
2
3
1
2
3
Operation
19
18
Operation
Key Tones
Mode
Key Tones Mode On and Off
Press Menu/Enter knob and rotate clockwise
to Set Key Tones. Press Menu/Enter to set Key
Tones On/Off.
Press Menu/Enter knob to select On/Off and
exit to main menu.
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/ WX
D
IM
SCAN
SET KEY TONES
ON
OFF
Note
Press Dim/Escape
button to return to CB mode.
Setting the
Alarm continued
Once alarm settings are complete, rotate Menu/Enter
knob clockwise to Set Snooze and press to select.
Enter desired snooze time (from 1 to 60 minutes).
Select Enter to exit, return to Set Snooze or Alarm
Length. Select Alarm Length to set alarm duration
(from 10 to 300 seconds). Pressing Menu/Enter
knob returns unit to exit, Set Snooze or Alarm
Length.
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/WX
DIM
SCAN
EXIT
SET SNOOZE
ALARM LENGTH
Note
Default snooze time length
is 10 minutes.
Note
Press Dim/Escape button to
return to CB standby mode.
Note
Default alarm length
is 60 seconds and is set in
10 second increments.
Setting the
Count Down
Timer
SWR/CAL
NB/ANL
VOL SQ DYNAMIKERF GAIN DELTA TUNE
T BACK
SWR
CAL
OFF MIN
MINOFF
MAX
ESC
MEM SCAN
S/RF
M
E
N
U
P
U
S
H
E
N
T
E
R
SIG
RF
+30dB
1
1.5
2
3
CAL
3
5
7
9
SWR
TX
RX
NB/ANL
MEMWX !
ANL
S/RF
SWR
CAL
CH 9/
19
CB/ WX
DIM
SCAN
SET CLOCK
SET ALARM
SET COUNT DOWN
Note
Press Dim/Escape button to
return to CB standby mode.
29LXBT_MANL_vH.indd 18-19 5/22/14 7:37 AM