Burner and nozzle specifications tables
The nozzles not provided are available at Authorised Service Centres.
Natural gas G20 – 20 mbar AUX SR UR
Rated heating capacity (kW)
1.05 1.8 3.9
Nozzle diameter (1/100 mm)
72 97 135
Pre-chamber (printed on nozzle)
(X) (Z) (S)
Reduced flow rate (W)
400 500 1600
LPG G30/31 – 30/37 mbar AUX SR UR
Rated heating capacity (kW)
1.05 1.8 3.9
Nozzle diameter (1/100 mm)
50 65 100
Pre-chamber (printed on nozzle)
---
Reduced flow rate (W)
400 500 1600
Rated flow rate G30 (g/h)
76 131 284
Rated flow rate G31 (g/h)
75 129 279
Town gas G110 – 8 mbar AUX SR UR
Rated heating capacity (kW)
1.05 1.8 3.9
Nozzle diameter (1/100 mm)
145 185 340
Pre-chamber (printed on nozzle)
/8 /2 /13
Reduced flow rate (W)
400 500 1200
Town gas G120 – 8 mbar AUX SR UR
Rated heating capacity (kW)
1.05 1.8 3.9
Nozzle diameter (1/100 mm)
135 175 315
Pre-chamber (printed on nozzle)
/8 /2 /13
Reduced flow rate (W)
400 500 1400