Instructions for the installer
32
5.5 Regulation of primary air
Referred to distance “X” in mm.
Burner
G20
20 mbar
G30/G31 G110
30/37 mbar 8 mbar
Auxiliary (1) 1.5 1.0 0.5
Semirapid (2) 1.5 1.5 0.5
Rapid (3) 1.0 1.5 1.0
Rapid large (4) 2.5 10.0 1.5
Fish pan (7) 2.0 2.5 1.0
Ultra rapid (5) 2.0 2.5 1.5
Internal 3 6.0 1.0
Double
crown (6)
External 3.0 10.0 5.0
To identify the burners on your hob, refer to the drawings in point “6.3 Arrangement of burners
on hob “