Loading ...
Loading ...
Loading ...
JENN-AIR
®
DETAILED PLANNING DIMENSIONS
4 of 4
8576BdZw815
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
DOWNDRAFT RANGE DUCTING ARRANGEMENTS
CALCULATING MAXIMUM DUCTING LENGTH
Maximum ducting length is 60' (18.3 m).
Each 90° elbow equals 5' (1.5 m) duct.
Use no more than three 90° elbows.
Flexible metal vent is not recommended.
• Do not install two elbows together.
NOTES:
For ducting runs up to 30' (9.1 m), install range as shipped.
For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the
restricter ring on the blower inlet housing.
For altitudes above 4500' (1272.0 m), reduce recommended
vent run by 20% for best performance.
DUCTING REQUIREMENTS
RANGE DUCT LENGTH DUCT SIZE
Dual Fuel
10' (3.0 m) or less*
5" (12.7 cm)
diameter*
Between 10' (3.0 m)
and 60' (18.3 m)
6" (15.2 cm)
diameter
3
1
4" x 10"
(8.3 cm x 25.4 cm)
Electric
10' (3.0 m) or less**
5" (12.7 cm)
diameter**
Between 10' (3.0 m)
and 60' (18.3 m)
6" (15.2 cm)
diameter
3
1
4" x 10"
(8.3 cm x 25.4 cm)
* Dual fuel ranges must use 5" (12.7 cm) diameter for runs of 10' (3.0 m)
or less.
** May be used to vent straight out the back of the range and directly
through the wall.
5" (12.7 cm)
diameter duct
to 3
1
4
1
" x 10"
(8.3 cm x 25.4 cm)
transition elbow
5" (12.7 cm)
diameter duct
5" (12.7 cm)
diameter wall cap
REAR DUCTING THROUGH WALL TO OUTSIDE
REAR DUCTING IN WALL TO ROOF
DUCTING CONFIGURATIONS
5" (12.7 cm)
to 6" (15.2 cm)
diameter
transition elbow
6" (15.2 cm)
diameter wall cap
THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE
DUCT-FREE INSTALLATION THROUGH RANGE FRONT