Loading ...
Loading ...
Loading ...
15
The “Vent System Charts” provides venting requirements that
will help achieve best drying performance.
Special provisions for mobile home
installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed
for best drying performance:
Use following “Vent System Charts” to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in “Vent System Charts.” Exhaust systems longer than those
specied will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1-866-698-2538, or visit us
at www.whirlpoolparts.com. In Canada, call
1-800-688-2002 or visit us at www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP 0–5" Metal vent periscope
4396037RP 0"–18" Metal vent periscope
4396011RP 18"–29" Metal vent periscope
4396014 29"–50" Metal vent periscope
4392892 In-Wall metal DuraVent™ Periscope
4396028 Sure Connect™ venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, exible dryer venting
4396010RP 6' SecureConnect™ vent, exible dryer venting
4396013RB Dryer vent installer’s kit
4396033RP 5' exible dryer venting with clamps
4396727RP 8' exible dryer venting with clamps
4396004 Dryer offset elbow
4396005 Wall offset elbow
4396006RW DuraSafe™ close elbow
4396007RW Through-the-wall vent cap
4396008RP 4" steel dryer venting clamps – 2 pack
8212662 Flush mounting louvered vent hood 4"
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
Vent System Chart
Loading ...
Loading ...
Loading ...