User Manual Leviton LTB30-1LZ Decora Electronic Countdown Timer Switch

Documents for Leviton LTB30-1LZ

The following documents are available:
Installation Instruction Specification
  • Specification Sheet - (English) Download
Warranty Photos
LTB30-1LZ photo
Single Pole (One location) or 3-Way (Multi-location)
Electronic Countdown Timer Switch
Cat. No. LTB15, LTB30, LTB60, LTB02, LTB12 Lighted
20A Resistive/Inductive, 1800W Incandescent, 1HP
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.
• Levitonelectroniccountdowntimerswitchesarenotcompatiblewithstandard3-wayor4-wayswitches.Theymustbeusedwithcompatible
Vizia
+
®
ON/OFFremoteswitches.
• Recommendedminimumwallboxdepthis2-1/2”.
WARNINGS AND CAUTIONS:
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Useonlyone(1)Levitonelectroniccountdowntimerswitchinamulti-locationcircuitwithupto9coordinatingremoteswitches
withoutLEDsorupto4matchingremoteswitcheswithLEDs
.
• Maximumwirelengthfromtimerswitchtoallinstalledremoteswitchescannotexceed300ft(90m).
• Usethisdeviceonlywithcopper or copper clad wire only.
IMPORTANT:For3-Wayapplications,notethatoneofthescrewterminals
fromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)
orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthe
common(LineorLoad)inboththeswitchwallboxandremotewallbox.
TOOLS NEEDED TO INSTALL YOUR TIMER SWITCH
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Pencil Cutters Ruler
WIRING TIMER SWITCH:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenlead.
• LineHotwallboxwiretoBlacklead.
• LoadwallboxwiretoRedlead.
• LineNeutralwallboxwiretoWhitelead.
• TimerSwitchYellow/RedleadshouldhaveRedinsulationlabelafxed.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
Coordinating Remote Switch (no LED)
YL/RD
YL/RD
RD
WH
RD
BK
Bla c k
BK WH
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
(u n used )
(u n used )
Load
Timer Switch
WIRING TIMER SWITCH:
Connect wires per WIRING DIAGRAM as follows:
NOTE:ThetimerswitchmustbeinstalledinawallboxthathasaLine
Hot connection.
NOTE:Maximumwirelengthfromtimerswitchtoallinstalledremote
switchescannotexceed300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenlead.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchtoBlacklead.
• FirstTravelerwallboxwiretoRedlead(note wire color).
• RemoveRedinsulatinglabelfromYellow/Redlead.
• SecondTravelerwallboxwiretoYellow/Redlead(note wire color).
Thistravelerfromthetimerswitchmustgototheterminalscrewon
theremoteswitchmarked"YL/RD".
• LineNeutralwallboxwiretoWhitelead.
WIRING VIZIA COORDINATING REMOTE SWITCH:
Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteswitchare
unused.Tightenbothscrews.
NOTE:Maximumwirelengthfromtimerswitchtolastremoteswitch
is300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
First Traveler (note color as above).
• SecondTravelerwallboxwire(note color as above)toterminal
screwmarked"YL/RD".Thistravelerfromtheremoteswitchmustgo
totheYellow/Redleadofthetimerswitch.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".
• ProceedtoStep5.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER atcircuitbreakerorfuseandtestthatpoweris
offbeforewiring!
Step 1
2
4
3
1
2
4
1
5
3
Single Pole
1. Line (Hot)
2. Neutral
3.Ground
4. Load
3-Way
1. Line or Load
(see
IMPORTANT
instruction)
2. Neutral
3.Ground
4. First Traveler – note color
5. Second Traveler – note
color.
Identifying your wiring application (most common):
NOTE:Ifthewiringinyourwallboxdoesnotresembleanyof
thesecongurations,consultanelectrician.
Step 2
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.
1
2
Black
White
Red
4
Yellow/Red
Green
3
Single Pole Wiring Application:
Step 4a
Step 4a cont'd
2
1
4
BK
RD
YL/RD
Coordinating Remote Switch Timer Switch
5
3
1
2
Black
White
Red
4
Yellow/Red
Green
3
5
WH
3-Way Wiring with Vizia
+
Coordinating Remote
Switch (no LED) Application:
Step 4b
• Makesurethattheendsofthewiresfromthewallboxare
straight (cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
• ForSingle-PoleApplication,gotoStep4a.
• For3-WayCoordinatingRemoteSwitch(noLEDs)Application,gotoStep4b.
• For3-WayMatchingRemoteSwitch(withLEDs)Application,gotoStep4c.
Step 3
Preparing and connecting wires:
Pulloffpre-cutinsulationfromtimerswitchleads.Makesure
thattheendsofthewiresfromthewallboxarestraight(cutif
necessary).Removeinsulationfromeachwireinthewallbox
asshown:
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Step 4b cont'd
Changing the color of your device:
Yourdevicemayincludecoloroptions.Tochangecoloroftheface,
proceedasfollows:
Push in side
at tab to release
Line up tabs and
press in sides one
at a time to attach
For non-standard wiring applications, refer to
Wire Nut and Connector Size Chart
WIRE CONNECTOR / # OF COND. COMBINATION CHART
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 to 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
Timer Switch
Insulating
Label
Black
Hot (Black)Black
Line
120 VAC, 60Hz
Neutral (White)
Red Yellow/Red
White
White
Green
Ground
Load
PK-93796-10-00-2A
NOTE:UsecheckboxeswhenStepsarecompleted.
INSTALLING YOUR TIMER SWITCH
+
MAXIMUM LOAD PER TIMER FOR MULTI-DEVICE INSTALLATIONS
Load Single TwoDevices More than 2 devices
Resistive Load 20A(2400W) 16A(1920W) 16A(1920W)
Incandescent Load
1800W 1800W 1800W
Inductive Load 20A 16A 16A
Motor Load 1HP 1HP 1HP
NOTE:Formatchingremotew/LEDsinstallation,
the First TravelerbecomesLineHot.
Loading ...