This dryer is equipped for use with natural gas. It is design-
cered by CSA Internaonal for LP (propane and butane)
gases with appropriate conversion. No aempt shall be made
to convert dryer from gas specied on serial/rang plate for use
with a dierent gas without consulng the serving gas supplier.
Conversion must be done by a qualied service technician.
Gas conversion kit part numbers are listed on gas valve burner
base.
Type of Gas
GAS SUPPLY CONNECTION

Provide a gas supply line of 1⁄2" (13 mm) rigid (IPS) pipe to
dryer locaon. Pipe joint compounds that resist acon of LP
gas must be used. Do not use TEFLON®† tape. With LP gas,
piping or tubing size can be 1⁄2" (13 mm) minimum. Usually,
LP gas suppliers determine size and materials used in the
system.
Gas Supply Pressure Testing
A 1/8" (3 mm) NPT minimum plugged tapping, accessible for
gauge tesng, must be installed immediately downstream of
the installed shut-o valve to the dryer (as shown above). The
dryer must be disconnected from the gas supply piping system
during any pressure tesng of the system at test pressures in
excess of 1/2" psig (352 kg/m
2
).
Alternate Method
The gas supply may also be connected using 38" (10 mm)
approved copper or aluminum tubing. If the total length of
the supply line is more than 20 . (6.1 m), larger tubing will
be required.
If using natural gas, do not use copper tubing. Pipe joint
compounds that resist acon of type of gas supplied must
be used.

The supply line must be equipped with a manual shut-o
valve installed within 6 . (1.8 m) of dryer in accordance
with Naonal Fuel Gas Code, ANSI Z223.1. This valve should
be located in same room as dryer. It should be in a locaon
that allows ease of opening and closing. Do not block access to
shut-o valve. In Canada, an individual manual shut-o valve
must be installed in accordance with the B149 installaon
codes CAN/CGA B149.1 and CAN/CGA B149.2.
Gas Supply Line

It is recommended that a new exible stainless steel gas line,
design-cered by CSA Internaonal, be used for connecng
the dryer to the gas supply line. (The gas pipe which extends
through the lower rear of the dryer is provided with 38"
[10 mm] male pipe thread.)
Do not kink or damage the exible stainless steel gas
line when moving the dryer.

The rigid pipe connecon requires a combinaon of pipe
ngs to obtain an in-line connecon to the dryer.