Electric/Gas Dryer
PRODUCT MODEL NUMBERS
W10757741A
05/2016
WED9000F, WED9500E, WGD9000F, WGD9500E
Recommended installation clearances (dryer only):
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
DRYER DIMENSIONS
NOTE: Most installations require a minimum of 6" (152 mm)
clearance behind dryer for exhaust vent with elbow. See
“Venting Requirements.”
Bottom view:
8
1
/2"
(218 mm)
14
3
/8"
(365 mm)
41
3
/8"
(1050 mm)
3
5
/8"
(93 mm)
1"
(25 mm)
33
1
/2"
(851 mm)
57
5
/8"
(1464 mm)
11
3
/8"
(289 mm)
Door Opened
Door Closed
5
7
/8"
(150 mm)
3
1
/2"
(93 mm)
4
1
/2"
(115 mm)
3"
(77 mm)
29"
(737 mm)
14
1
/2"
(370 mm)
1
3
/8"
(35 mm)
Back view
Side view
Whirlpool Model
Bottom view:
8
1
/2"
(218 mm)
14
3
/8"
(365 mm)
41
11
/16"
(1103 mm)
3
5
/8"
(93 mm)
1"
(25 mm)
33
1
/2"
(851 mm)
57
5
/8"
(1464 mm)
11
3
/8"
(289 mm)
Door Opened
Door Closed
5
7
/8"
(150 mm)
3
1
/2"
(93 mm)
4
1
/2"
(115 mm)
3"
(77 mm)
29"
(737 mm)
14
1
/2"
(370 mm)
1
3
/8"
(35 mm)
Back viewSide view
Maytag Model
6"/0"
(152 mm/0 mm)
14" max
(356 mm)
1"/0"
(25 mm/0 mm)
1"/1"
(25 mm)
18"/18"*
(457 mm)
3"/3"
(76 mm)
3"/3"
(76 mm)
48"
2
/48"
2
(310 cm
2
)
24"
2/
24"
2
(155 cm
2
)
Recommended/Minimum spacing
Companion appliance spacing should also be considered.
background
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
ELECTRICAL REQUIREMENTS
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
Louvered Hood
Angled Hood
Box Hood
Exhaust hoods:
Recommended Styles:
Acceptable Style:
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
WATER (STEAM MODELS ONLY) REQUIREMENTS
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
INSTALLATION REQUIREMENTS
Determine vent length and elbows needed for best
drying performance:
Use following Vent System Chart to determine type of vent material
and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those specied will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also
recommended that a separate circuit serving only this dryer be provided.
To supply the required 3- or 4-wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3- or 4-wire, 120/208 volt electrical supply, if
specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not
have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Must be at least 12" (305 mm) from ground or any object that may
obstruct exhaust (such as owers, rocks, bushes, or snow).
The Vent System Charts provide venting requirements that will help
achieve best drying performance.
Vent System Chart
Number of
90° elbows
Type of vent Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
NOTE: Bottom exhaust installations have a 90° turn inside the
dryer. To determine maximum exhaust length, add one 90° turn
to the charts.

Specifications