7. Press the CLEAN button. See “Using the Controls.” The
Clean button will blink, indicating that the cleaning cycle is in
process. When the “Cleaning Complete” light is illuminated
(approximately 70 minutes), the cleaning cycle is complete.
During the cleaning cycle, the system will both clean and
rinse itself.
8. After the cleaning cycle is complete, remove the drain cap
from the water pan. Look for any cleaning solution left in the
water pan. If cleaning solution drains from the water pan, you
should run the clean cycle again. Be sure to refill the water
pan with cleaner before starting the clean cycle again. Be
sure to replace the drain cap securely on the water pan. If the
drain cap is loose, water will empty from the water pan and
you will have either thin ice or no ice.
NOTE: Severe scale buildup may require repeated cleaning with
a fresh quantity of cleaning solution.
9. Press the ON/OFF button to resume ice production.
Condenser
A Dirty or Clogged Condenser
Obstructs proper airflow.
Reduces ice making capacity.
Causes higher than recommended operating temperatures
which may lead to component failure.
1. Unplug ice maker or disconnect power.
2. Remove the 2 screws in the lower access panel and the
2 screws from the base grille area of the front panel support.
3. Pull the bottom forward, and then pull down to remove the
lower access panel.
4. Remove dirt and lint from the condenser fins and the unit
compartment with a brush attachment on a vacuum cleaner.
5. Replace the lower access panel using the 4 screws.
6. Plug in ice maker or reconnect power.
Interior Components
1. Unplug ice maker or disconnect power.
2. Open the storage bin door and remove any ice that is in the
bin.
3. Remove the drain cap from the water pan and drain
thoroughly. Replace the drain cap securely on the water pan.
If the drain cap is loose, water will empty from the water pan,
and you will have either thin ice or no ice.
4. Pull out on the bottom of the cutter grid cover until the snaps
release to remove.
5. Unplug the wiring harness from the left side of the cutter grid.
6. Unplug the ice level sensor from the right side of the cutter
grid. Pull the ice level sensor down and forward away from
the cutter grid.
7. Remove the right-hand and left-hand screws. Lift the cutter
grid up and out.
NOTE: Make sure the plastic spacer from the right-hand side
of the cutter grid bracket stays with the cutter grid.
8. Remove the mounting screw that holds the water pan in
place. Pull out on the front of the water pan.
A. Condenser fins
WARNING
Electrical Shock Hazard
Disconnect power before cleaning.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
A. Cutter grid cover
A. Cutter grid harness
B. Screw
C. Cutter grid
D. Ice level sensor harness
E. Plastic spacer
F. Sc r ew
A
A
B
C
D
E
F