Loading ...
Loading ...
Loading ...
Drain Hose Installation for Heating (On Some Models)
Indoor Drainage
CAUTION
• If you use the Heat mode, you must install the drain hose. If only the Cool mode is used, the
drain hose is not needed.
• If the outside temperature is at or near freezing 32 °F (0 °C) follow the indoor drainage
instructions.
• When the weather is above freezing, the unit can be set up to drain to the outside. Make sure the
outlet of the hose is aimed away from nearby surfaces that could be stained or damaged by the
draining water.
1. To attach the drain hose, insert the connector into the pump drain port at the back of the unit until it
snaps into place.
2. Place the other end of the drain hose in a bucket that holds at least 28 ounces. Remember to
check and empty the bucket frequently to avoid overflows.
3. To detach the drain hose from the product, push the outer ring of the pump drain port in and pull
the connector out.
NOTE
• Inserting the drain hose into the unit will automatically activate the drain function.
ENGLISH
INSTALLATION
15
Loading ...
Loading ...
Loading ...