Always follow all safety precautions when performing maintenance to the PowerMate.
WARNING
Electrical Shock Or Personal injury Hazard
Always turn off and unplug vacuum
cleaner before performing maintenance
to the vacuum cleaner. Failure to do so
could result in electrical shock or personal
injury from vacuum cleaner suddenly
starting.
BELTCHANGING AND AGITATOR CLEANING
TO REMOVE BELT
1. Turn off and unplug vacuum cleaner.
2. Turn PowerMate upside down.
3. Unscrew the two (2) PowerMate cover
screws.
4. Turn
PowerMate top
side up. Press
handle release
pedal and lower
the swivel Lift
rear latches up.
Latch
Latches
5. To remove cover,
grasp the sides and
pull out.
6. Liftagitator
assembly out
and remove
worn belt.
End Cap
7. Check and clean end cap areas. See
AGITATOR ASSEMBLY (page 24) for picture
of complete agitator assembly.