13
3. Depending on your model, remove plastic tag holding three
10-32 hex nuts from the middle post of the terminal block.
OR
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
4. Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the power supply cord.
Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Remove the knockout as needed for the flexible conduit
connection.
Assemble a UL listed conduit connector in the opening.
A. Removable retaining nut
B. Conduit
Tighten strain relief screw against the flexible conduit.
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL Listed, 250 V
minimum, 40 A,
range power
supply cord
4-wire connection:
Power supply cord
4-wire direct
A circuit breaker
box or fused
disconnect
4-wire connection:
Direct wire
3-wire receptacle
(NEMA type 10-50R
A UL Listed, 250 V
minimum, 40 A,
range power
supply cord
3-wire connection:
Power supply cord
3-wire direct
A circuit breaker
box or fused
disconnect
3-wire connection:
Direct wire