Problem Possible Causes What To Do
Air conditioner The air conditioner Make sure the air conditioner plug is pushed completely
does not start is unplugged. into the outlet.
The fuse is blown/circuit Check the house fuse/circuit breaker box and replace
breaker is tripped. the fuse or reset the breaker.
Power failure. If power failure occurs, turn the mode control to OFF.
When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor
overload.
Air conditioner does not Airflow is restricted. Make sure there are no curtains, blinds or furniture
cool as it should blocking the front of the air conditioner.
The temp control may not On models with touch pads: In COOL mode, press the
be set correctly. DECREASE pad.
On models with control knobs, turn the temperature
knob to a higher number.
The air filter is dirty. Clean the filter at least every 30 days.
See the Operating Instructions section.
The room may have been hot. When the air conditioner is first turned on you need to
allow time for the room to cool down.
Cold air is escaping. Check for open furnace floor registers and cold air returns.
Set the air conditioner’s vent to the closed position.
Cooling coils have iced up. See Air conditioner freezing up below.
Air conditioner Ice blocks the air flow On models with control knobs, set the mode control at
freezing up and stops the air conditioner HIGH FAN or HIGH COOL with the temp at 1 or 2.
from cooling the room.
On models with touch pads, set the mode control at
HIGH (F3) FAN or HIGH (F3) COOL and set the thermostat
to a higher temperature.
The remote control is The batteries are inserted Check the position of the batteries. They should be
not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Excessively hot and humid This is normal.
weather.
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture is removed from This is normal for a short period in areas with little
base pan indoor air and drains into humidity; normal for a longer period in very humid areas.
rear of a cabinet where a fan
blows it against the outdoor
condenser coil.