OPERATING INSTRUCTIONS
GAS SUPPLY
Your heater is fitted with a flexible hose and bayonet coupling which enables you to connect or disconnect
it from the gas supply.
TO CONNECT
Insert the coupling end into the wall bayonet fitting firmly and rotate the knurled section clockwise to it’s locked
position.
TO DISCONNECT
Apply firm forward pressure to the knurled area, rotate anti clockwise and pull towards you. The hose
should now come away from the wall bayonet fitting. Gas is automatically isolated when the hose is disconnected.
ELECTRICAL SUPPLY
Your heater is fitted with a power supply lead, which should be connected to a standard domestic socket.
POWER FAILURE
Your OMEGA ALTISE heater will operate normally in the event of a power failure. Should
the power fail while the heater is operating, the fan will stop. There is however, no need for concern as
your heater has been designed to operate satisfactorily with the fan off. Should you wish to ignite your
heater during a power failure, follow the instructions under Manual Ignition. Note: If your heater has
been disconnected for some time, there will be air in the flexible hose. It will therefore take a little longer
to ignite when you first turn it on.
MANUAL IGNITION
The heater may be manually lit by opening the dress guard (see Cleaning) and while holding down the
ignition button, apply a lighted long-reach match or taper to the pilot. The ignition button needs to be
held down for 20 seconds to allow the valve to lock in. Close up the dress guard as described in the
cleaning section.
ABNORMAL OPERATION
As the heater heats up or cools down, expansion or contraction takes place and the occasional
click’ may be heard. This is normal, however, continuous metallic noises, grinding sounds, the smell of
gas or any of the symptoms listed on the fault finding chart should be investigated immediately. Turn the
appliance off and disconnect the gas and electrical supplies. If the fault cannot be fixed or any doubts
exist, contact your nearest OMEGA ALTISE service agent or contact OMEGA ALTISE on the telephone
number on the rear page of this booklet.
CONTROLS
The heating controls and fan switches are located under a lid situated on the top right hand side of
the heater. Lighting instructions are affixed to the underside of the lid.
FAN AND FAN SWITCH
The two-speed fan is controlled by the fan switch in the control box, and, as indicated on the control box
lid label, the switch has three positions, slow, off and fast.
Selection of slow or fast fan speed in conjunction with High, Medium or Low heat settings is determined by
personal choice and/or heating requirements at the time.