Operating Modes
You can use this appliance in the air extraction or the
recirculation mode.
Exhaust air mode
The air that is drawn in is cleaned by the
grease lters and conveyed to the
exterior by a pipe system.
Note: Ventilation may not exit through an already
operational smoke or exhaust chimney, nor a duct used
for ventilating furnace installation areas.
If the ventilation is intended to pass through a smoke
or exhaust chimney that is not in operation, the
responsible area heating inspector must give approval.
If the ventilation passes through an external wall, use a
telescope wall sleeve.
Circulating-air mode
The air that is drawn in is cleaned by the
grease lters and an activated carbon
lter and conveyed back into the kitchen.
Note: To bind odors in circulating-air mode, you must
install an activated carbon lter. The different options for
operating the appliance in circulating-air mode can be
found in the brochure. Alternatively, ask your dealer. The
required accessories are available for purchase from spe-
cialist retailers, from customer service or from the Online
Shop.
The accessory numbers can be found at the end of the
instructions for use.
Operating the Appliance
These instructions apply to several appliance models. It
is possible that individual features are described that do
not apply to your appliance.
Note: Turn the extractor hood on when you start cooking
and switch it off again a few minutes after you have
nished cooking. This is the most effective way to
eliminate cooking vapor.
Control panel
Explanation
1 Turn the fan down 4 Switch on lighting
2 Turn the fan up 5 Timer
3 Display panel
Turn on the fan
Note: Always adjust the fan strength to meet current
conditions. If there is a large build-up of steam or fumes,
select a high fan setting.
Switching on
Press “+” button.
The current ventilator settings are indicated by a bar
on the display panel.
Press “+” or “-” keys to change the ventilator settings.
Switching off
Press the “-” button repeatedly until the ventilator
switches off.
Lighting
The lighting can be switched on and off independently of
the ventilation.
1. Press the “Light” button.
The lighting switches on.
2. Press the “Light” button again.
The brightness increases.
3. Press the “Light” button a third time.
The lighting switches off.
Saturation notification
The saturation of the metal grease lter (after 30 hours of
ventilation operation) or of the activated carbon lter
(after 120 hours of ventilation operation) is indicated on
the display panel:
Metal grease filter: “clean grease lter” appears on
the display panel.
Activated carbon filter: “replace charcoal lter”
appears on the display panel.
If you have not yet done so, the metal mesh grease lters
should be cleaned or the activated carbon lter changed
now.
For instructions on how to clean the metal grease lters,
please refer to the Cleaning and maintenance section.