Error Codes and Solutions for LOKITHOR Jump Starter with Air Compressor

Follow the recommended steps to troubleshoot and resolve these errors, maintaining your device in optimal condition.

Error 001

Explanation: When charging or starting, other functions are not available.

Solution: Disconnect the charger or exit the start mode.

Error 110

Explanation: Charging overvoltage protection.

Solution: Disconnect the charger.

Error 111

Explanation: Charging over-voltage (secondary) protection.

Solution: Disconnect the charger.

Error 120

Explanation: Charging over temperature protection.

Solution: Wait for the product to cool down.

Error 130

Explanation: Charging under temperature protection.

Solution: Put the product at the right temperature.

Error 140

Explanation: Discharge undervoltage protection.

Solution: Connect the charger.

Error 150

Explanation: Discharge over temperature protection.

Solution: Wait for the product to cool down.

Error 160

Explanation: Discharge under temperature protection.

Solution: Put the product at the right temperature.

Error 200

Explanation: Communication abnormal.

Solution: Restart the device.

Error 310

Explanation: Air inflator short-circuit protection.

Solution: Restart the device.

Error 320

Explanation: Air inflator over-current protection.

Solution: Restart the device.

Error 330

Explanation: When starting, the current air pressure is greater than the set air pressure.

Solution: Reset the proper air pressure.

Error 410

Explanation: When starting, under-voltage protection.

Solution: Connect the charger.

Error 411

Explanation: Before starting, under-voltage protection.

Solution: Connect the charger.

Error 420

Explanation: Start over temperature protection.

Solution: Wait for the product to cool down.

Error 430

Explanation: The external battery voltage is greater than the device voltage.

Solution: 1. The display voltage is lower than 12V, and the device voltage is low. Please connect the charger to recharge.
2. If the display voltage is higher than 12V, the car battery is normal, or the car battery voltage is too high, which is not suitable for this product. Please use a jump starter that supports higher voltage.

Error 440

Explanation: Ignition clip shorted.

Solution: Connect the battery correctly.

Error 450

Explanation: Ignition clip shorted.

Solution: Connect the battery correctly.

Error 460

Explanation: Short circuit protection.

Solution: Restart the device.

Error 470

Explanation: Abnormal cell voltage drift protection.

Solution: /

Error 480

Explanation: Continuous start protection.

Solution: Wait 30 seconds and start again.

 

Find LOKITHOR user manual at here.

T: @ManualsFile

https://ManualsFile.com

Mon - Sun 09:30 am - 05:30 pm