User Manual First Alert ‎SCO5CN SCO5CN Combination Smoke and Carbon Monoxide Detector, Battery Operated

Documents for First Alert SCO5CN

The following documents are available:
User Manual Other Documents Photos
SCO5CN photo
Model SCO5
M08-0117-011 Q 06/12 Printed in Mexico
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information
about your Combination Carbon Monoxide & Smoke
Alarm’s operation. If you are installing this Alarm for
use by others, you must leave this manual—or a copy
of it—with the end user.
© 2012 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 www.firstalert.com
INTRODUCTION
FIRE SAFETY TIPS
F
ollow safety rules and prevent hazardous situations: 1) Use smoking
m
aterials properly. Never smoke in bed. 2) Keep matches or lighters away
f
rom children; 3) Store flammable materials in proper containers; 4) Keep
electrical appliances in good condition and don’t overload electrical circuits;
5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-
free; 6) Never leave anything cooking on the stove unattended; 7) Keep
portable heaters and open flames, like candles, away from flammable
materials; 8) Don’t let rubbish accumulate.
K
eep alarms clean, and test them weekly. Replace alarms immediately if
t
hey are not working properly. Smoke Alarms that do not work cannot alert
y
ou to a fire. Keep at least one working fire extinguisher on every floor, and
a
n additional one in the kitchen. Have fire escape ladders or other reliable
m
eans of escape from an upper floor in case stairs are blocked.
BASIC SAFETY INFORMATION
Dangers, Warnings, and Cautions alert you to important
o
perating instructions or to potentially hazardous situations.
P
ay special attention to these items.
This Smoke/CO Alarm is approved for use in single-family
residences. It is NOT designed for marine or RV use.
T
his combination Smoke/Carbon Monoxide Alarm has two separate
a
larms. The CO Alarm is not designed to detect fire or any other
g
as. It will only indicate the presence of carbon monoxide gas at
t
he sensor. Carbon monoxide gas may be present in other areas.
T
he Smoke Alarm will only indicate the presence of smoke that
r
eaches the sensor. The Smoke Alarm is not designed to sense
g
as, heat or flames.
This Smoke/CO Alarm cannot operate without working batteries.
Removing the batteries for any reason, or failing to replace the
batteries at the end of their service life, removes your protection.
NEVER ignore any alarm. See “If Your Smoke/CO Alarm Sounds”
f
or more information on how to respond to an alarm. Failure to
r
espond can result in injury or death.
The Silence Features are for your convenience only and will not
correct a problem. See "Using the Silence Features" for details.
Always check your home for a potential problem after any alarm.
Failure to do so can result in injury or death.
Test this Smoke/CO Alarm once a week. If the Alarm ever fails to
t
est correctly, have it replaced immediately! If the Alarm is not
w
orking properly, it cannot alert you to a problem.
This product is intended for use in ordinary indoor locations of
f
amily living units. It is not designed to measure CO levels in
c
ompliance with Occupational Safety and Health Administration
(
OSHA) commercial or industrial standards. Individuals with
m
edical conditions that may make them more sensitive to carbon
m
onoxide may consider using warning devices which provide
a
udible and visual signals for carbon monoxide concentrations
u
nder 30 ppm. For additional information on carbon monoxide
a
nd your medical condition contact your physician.
FCC Compliance
T
his equipment has been tested and found to comply with the limits for a
C
lass B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that of
the receiver.
Consult the dealer or an experienced radio or TV technician for help.
Warning: Changes or modifications to the product, not expressly approved
by First Alert / BRK Brands, Inc., could void the user’s authority to operate
the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
5 6 71 2 3
COMBINATION CARBON MONOXIDE & SMOKE ALARM
4
Printed in Mexico M08-0117-011 Q 06/12
First Alert
®
is a registered trademark of the First Alert Trust.
WHAT YOU NEED TO KNOW ABOUT CO
WHAT IS CO?
C
O is an invisible, odorless, tasteless gas produced when fossil fuels do not
b
urn completely, or are exposed to heat (usually fire). Electrical appliances
t
ypically do not produce CO.
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline,
kerosene, and propane.
C
ommon appliances are often sources of CO. If they are not properly main-
t
ained, are improperly ventilated, or malfunction, CO levels can rise quickly.
C
O is a real danger now that homes are more energy efficient. “Air-tight”
h
omes with added insulation, sealed windows, and other weatherproofing
c
an “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed
with ALL household members.
M
ild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).
Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate.
Extreme Exposure: Convulsions, unconsciousness, heart and lung failure.
Exposure to Carbon Monoxide can cause brain damage, death.
This CO Alarm measures exposure to CO over time. It alarms if CO levels are
extremely high in a short period of time, or if CO levels reach a certain mini-
mum over a long period of time. The CO Alarm generally sounds an alarm
before the onset of symptoms in average, healthy adults. Why is this important?
Because you need to be warned of a potential CO problem while you can still
react in time. In many reported cases of CO exposure, victims may be aware
that they are not feeling well, but become disoriented and can no longer
react well enough to exit the building or get help. Also, young children and
pets may be the first affected. The average healthy adult might not feel any
symptoms when the CO Alarm sounds. However, people with cardiac or
respiratory problems, infants, unborn babies, pregnant mothers, or elderly
people can be more quickly and severely affected by CO. If you experience
even mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it difficult
to locate the source of CO after an alarm. These are a few of the factors that
can make it difficult to locate sources of CO:
House well ventilated before the investigator arrives.
Problem caused by “backdrafting.”
Transient CO problem caused by special circumstances.
B
ecause CO may dissipate by the time an investigator arrives, it may be diffi-
c
ult to locate the source of CO. BRK Brands, Inc. shall not be obligated to
p
ay for any carbon monoxide investigation or service call.
POTENTIAL SOURCES OF CO IN THE HOME
F
uel-burning appliances like:
p
ortable heater, gas or wood burning
f
ireplace, gas kitchen range or cooktop,
g
as clothes dryer.
Damaged or insufficient venting:
corroded or disconnected water heater
vent pipe, leaking chimney pipe or flue,
or cracked heat exchanger, blocked or
c
logged chimney opening.
I
mproper use of appliance/device:
o
perating a barbecue grill or vehicle
i
n an enclosed area (like a garage or
s
creened porch).
T
ransient CO Problems: “transient” or on-again-off-again CO problems can
b
e caused by outdoor conditions and other special circumstances.
T
he following conditions can result in transient CO situations:
1. Excessive spillage or reverse venting of fuel appliances caused by outdoor
conditions such as:
Wind direction and/or velocity, including high, gusty winds. Heavy air in
the vent pipes (cold/humid air with extended periods between cycles).
Negative pressure differential resulting from the use of exhaust fans.
Several appliances running at the same time competing for limited
f
resh air.
Vent pipe connections vibrating loose from clothes dryers, furnaces, or
water heaters.
Obstructions in or unconventional vent pipe designs which can amplify
t
he above situations.
2. Extended operation of unvented fuel burning devices (range, oven, fireplace).
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home.
T
hese conditions are dangerous because they can trap exhaust in your home.
S
ince these conditions can come and go, they are also hard to recreate during
a
CO investigation.
HOW CAN I PROTECT MY FAMILY FROM
CO POISONING?
A
CO Alarm is an excellent means of protection. It monitors the air and sounds
a
loud alarm before Carbon Monoxide levels become threatening for average,
h
ealthy adults.
A CO Alarm is not a substitute for proper maintenance of home appliances.
T
o help prevent CO problems and reduce the risk of CO poisoning:
Clean chimneys and flues yearly. Keep them free of debris, leaves, and
n
ests for proper air flow. Also, have a professional check for rust and
c
orrosion, cracks, or separations. These conditions can prevent proper
a
ir movement and cause backdrafting. Never “cap” or cover a chimney
i
n any way that would block air flow.
Test and maintain all fuel-burning equipment annually. Many local gas
or oil companies and HVAC companies offer appliance inspections for
a nominal fee.
Make regular visual inspections of all fuel-burning appliances. Check
a
ppliances for excessive rust and scaling. Also check the flame on the
b
urner and pilot lights. The flame should be blue. A yellow flame
m
eans fuel is not being burned completely and CO may be present.
K
eep the blower door on the furnace closed. Use vents or fans when
t
hey are available on all fuel-burning appliances. Make sure appliances
a
re vented to the outside. Do not grill or barbecue indoors, or in
g
arages or on screen porches.
Check for exhaust backflow from CO sources. Check the draft hood on
an operating furnace for a backdraft. Look for cracks on furnace heat
exchangers.
Check the house or garage on the other side of shared wall.
Keep windows and doors open slightly. If you suspect that CO is
escaping into your home, open a window or a door. Opening windows
and doors can significantly decrease CO levels.
I
n addition, familiarize yourself with all enclosed materials. Read this
m
anual in its entirety, and make sure you understand what to do if your
CO Alarm sounds.
REGULATORY INFORMATION FOR
SMOKE/CO ALARMS
REGULATORY INFORMATION FOR CO ALARMS
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO
Alarms to sound when exposed to levels of CO and exposure times as
described below. They are measured in parts per million (ppm) of CO over
time (in minutes).
UL2034 Required Alarm Points*:
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN
4 and 15 MINUTES.
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN
10 and 50 MINUTES.
If the alarm is exposed to 70 ppm if CO, IT MUST ALARM BETWEEN
60 and 240 MINUTES.
* Approximately 10% COHb exposure at levels of 10% to 95% Relative
Humidity (RH).
The unit is designed not to alarm when exposed to a constant level
of 30 ppm for 30 days.
CO Alarms are designed to alarm before there is an immediate life threat.
Since you cannot see or smell CO, never assume it’s not present.
An exposure to 100 ppm of CO for 20 minutes may not affect average,
healthy adults, but after 4 hours the same level may cause headaches.
An exposure to 400 ppm of CO may cause headaches in average, healthy
adults after 35 minutes, but can cause death after 2 hours.
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon
monoxide alarms UL2034.
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon
monoxide alarms covered by these requirements are intended to respond to the
presence of carbon monoxide from sources such as, but not limited to, exhaust
from internal-combustion engines, abnormal operation of fuel-fired appliances,
and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels
below those that could cause a loss of ability to react to the dangers of Carbon
Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is
designed to alarm before CO levels become life threatening. This allows you
precious time to leave the house and correct the problem. This is only possible
if Alarms are located, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm
is not formulated to detect CO levels below 30 ppm typically. UL tested for false
alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm),
Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000
ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85 dB minimum at 10 feet (3 meters).
REGULATORY INFORMATION FOR SMOKE ALARMS
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one Smoke Alarm
on every floor, in every sleeping area, and in every bedroom. In new construction,
the Smoke Alarms must be AC powered and interconnected. See “Agency
Placement Recommendations” for details.
Continued...
LIMITED WARRANTY
BRK Brands, Inc., ("BRK") the maker of First Alert
®
brand products warrants that for a period of seven years from the date of purchase, this product will be free from defects in
material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value.
This is your exclusive warranty. This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt.
Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way
change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use
contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God,
such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law,
any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do
not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not
apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005,
7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when calling.
For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect to battery.
ABOUT SMOKE ALARMS
B
attery (DC) operated Smoke Alarms: Provide protection even when
e
lectricity fails, provided the batteries are fresh and correctly installed. Units
a
re easy to install, and do not require professional installation.
A
C powered Smoke Alarms: Can be interconnected so if one unit senses
s
moke, all units alarm. They do not operate if electricity fails.
A
C with battery (DC) back-up: will operate if electricity fails, provided the
b
atteries are fresh and correctly installed. AC and AC/DC units must be
i
nstalled by a qualified electrician.
Smoke/CO Alarms for Solar or Wind Energy users and battery backup
power systems: AC powered Smoke/CO Alarms should only be operated
with true or pure sine wave inverters. Operating this Alarm with most battery-
powered UPS (uninterruptible power supply) products or square wave or
“quasi sine wave” inverters will damage the Alarm. If you are not sure about
your inverter or UPS type, please consult with the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms
should be installed for the hearing impaired. They include a visual alarm and an
audible alarm horn, and meet the requirements of the Americans With Disabilities
Act. Can be interconnected so if one unit senses smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the user’s manual, and if
smoke reaches the Alarm. If you are unsure which type of Smoke Alarm to
install, refer the National Fire Protection Association (NFPA) Standard 72
(National Fire Alarm and Signaling Code) and NFPA 101 (Life Safety Code).
National Fire Protection Association, One Batterymarch Park, Quincy, MA
02269-9101. Local building codes may also require specific units in new
construction or in different areas of the home.
F
eatures:
Separate sensors to detect smoke
and CO; the two alarm systems
work independently
Powered by two “AA” batteries
Side access drawer for easy
battery replacement
A
ll First Alert
®
S
moke Alarms conform to regulatory requirements,
i
ncluding UL217 and are designed to detect particles of combustion.
S
moke particles of varying number and size are produced in all fires.
Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spread quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
P
hotoelectric technology is generally more sensitive than ionization
t
echnology at detecting large particles, which tend to be produced in
g
reater amounts by smoldering fires, which may smolder for hours
b
efore bursting into flame. Sources of these fires may include cigarettes
b
urning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in every bedroom of your home.
SPECIAL COMPLIANCE CONSIDERATIONS
T
his Smoke Alarm is suitable for use in apartments, condominiums,
t
ownhouses, hospitals, day care facilities, health care facilities, boarding
h
ouses, group homes and dormitories provided a primary fire detection
s
ystem already exists to meet fire detection requirements in common areas
l
ike lobbies, hallways, or porches. Using this Smoke Alarm in common areas
m
ay not provide sufficient warning to all residents or meet local fire protection
o
rdinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete fire
detection systems in places housing many people—like apartment buildings,
condominiums, hotels, motels, dormitories, hospitals, health care facilities,
nursing homes, day care facilities, or group homes of any kind. It is not a
suitable substitute for complete fire detection systems in warehouses,
industrial facilities, commercial buildings, and special-purpose non-residential
b
uildings which require special fire detection and alarm systems. Depending
o
n the building codes in your area, this Smoke Alarm may be used to provide
a
dditional protection in these facilities.
I
n new construction, most building codes require the use of AC or AC/DC
p
owered Smoke Alarms only. In existing construction, AC, AC/DC, or DC
p
owered Smoke Alarms can be used as specified by local building codes.
R
efer to NFPA 72 (National Fire Alarm and Signaling Code) and NFPA 101
(
Life Safety Code), local building codes, or consult your Fire Department for
d
etailed fire protection requirements in buildings not defined as “households”.
H
UD MAP Program
C
ertain HUD battery powered Smoke Alarm applications, especially those
t
hat fall under HUD 223(f) MAP (Multi-family Accelerated Processing), may
r
equire a 10 Year sealed tamper resistant battery. This alarm does not meet
t
hat requirement. Substitute First Alert SA340B.
TROUBLESHOOTING GUIDE
I
f the Alarm... Problem... You should...
H
orn "chirps" about once per minute. Low battery warning. Install two new AA batteries*.
H
orn does three "chirps" every minute;
L
ED has 3 rapid flashes with "chirps".
M
ALFUNCTION SIGNAL. Device is not working
p
roperly, and needs to be replaced.
U
nits under warranty should be returned to
m
anufacturer for replacement. See “Limited
W
arranty” for details.
Carbon Monoxide Alarm ONLY:
CO Alarm goes back into alarm 4 minutes after you
Silence it.
CO levels indicate a potentially dangerous situation. IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call 911
or the Fire Department. Refer to "If The CO Alarm
Sounds" for details.
CO Alarm sounds frequently even though no high
levels of CO are revealed in an investigation.
The CO Alarm may be improperly located. Refer to
“Where to Install This Alarm” for details.
Relocate your Alarm. If frequent alarms continue,
have home rechecked for potential CO problems.
You may be experiencing an intermittent CO
problem.
Smoke Alarm ONLY:
Smoke Alarm sounds when no smoke is visible.
Unwanted alarm may be caused by non-emergency
source like cooking smoke.
Silence Alarm using Test/Silence button; clean the
Alarm’s cover with a soft, clean cloth. If frequent
unwanted alarms continue, relocate your Alarm.
Alarm may be too close to a kitchen, cooking
appliance, or steamy bathroom.
*For a list of acceptable replacement batteries, see “Regular Maintenance.”
If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)
The light flashes GREEN and the horn sounds
5 “chirps” every minute.
END OF LIFE SIGNAL.
Alarm needs to be replaced.
Immediately replace the Alarm.
This Smoke/CO Alarm is intended for residential use. It is not intended for use in
industrial applications where Occupational Safety and Health Administration (OSHA)
requirements for Carbon Monoxide Alarms must be met. The Smoke Alarm portion
of this device is not intended to alert hearing impaired residents. Special purpose
Smoke Alarms should be installed for hearing impaired residents (CO Alarms are
not yet available for the hearing impaired).
S
moke/CO Alarms may not waken all individuals. Practice the escape plan
a
t least twice a year, making sure that everyone is involved – from kids to grand-
p
arents. Allow children to master fire escape planning and practice before holding
a
fire drill at night when they are sleeping. If children or others do not readily waken
t
o the sound of the Smoke/CO Alarm, or if there are infants or family members with
m
obility limitations, make sure that someone is assigned to assist them in fire drill
a
nd in the event of an emergency. It is recommended that you hold a fire drill while
f
amily members are sleeping in order to determine their response to the sound of
t
he Smoke/CO Alarm while sleeping and to determine whether they may need
a
ssistance in the event of an emergency.
Smoke
/CO
Alarms cannot work without power. Battery operated units cannot work
if the batteries are missing, disconnected or dead, if the wrong type of batteries are
used, or if the batteries are not installed correctly. AC units cannot work if the AC
power is cut off for any reason (open fuse or circuit breaker, failure along a power line
or at a power station, electrical fire that burns the electrical wires, etc.). If you are
concerned about the limitations of battery or AC power, install both types of units.
This Smoke/CO Alarm will not sense smoke or CO that does not reach the
sensors. It will only sense smoke or CO at the sensor. Smoke or CO may be
present in other areas. Doors or other obstructions may affect the rate at which
CO or smoke reaches the sensors. If bedroom doors are usually closed at night,
we recommend you install an alarm device (Combination CO and Smoke Alarm, or
separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway
between them.
This Smoke/CO Alarm may not sense smoke or CO on another level of the
home. Example: This alarm device, installed on the second floor, may not sense
smoke or CO in the basement. For this reason, one alarm device may not give
adequate early warning. Recommended minimum protection is one alarm device in
every sleeping area, every bedroom, and on every level of your home. Some experts
recommend battery powered Smoke and CO Alarms be used in conjunction with
interconnected AC powered Smoke Alarms. For details, see “About Smoke Alarms”
for details.
S
moke/CO Alarms may not be heard. The alarm horn loudness meets or exceeds
c
urrent UL standards of 85 dB at 10 feet (3 meters). However, if the Smoke/CO
A
larm is installed outside the bedroom, it may not wake up a sound sleeper or one
w
ho has recently used drugs or has been drinking alcoholic beverages. This is
e
specially true if the door is closed or only partly open. Even persons who are awake
m
ay not hear the alarm horn if the sound is blocked by distance or closed doors.
N
oise from traffic, stereo, radio, television, air conditioner, or other appliances may
a
lso prevent alert persons from hearing the alarm horn. This Smoke/CO Alarm is
n
ot intended for people who are hearing impaired.
The Alarm may not have time to alarm before the fire itself causes damage,
injury, or death, since smoke from some fires may not reach the unit immedi-
ately. Examples of this include persons smoking in bed, children playing with
matches, or fires caused by violent explosions resulting from escaping gas.
This Smoke/CO Alarm is not a substitute for life insurance. Though this
Smoke/CO Alarm warns against increasing CO levels or the presence of smoke,
BRK Brands, Inc. does not warrant or imply in any way that they will protect lives.
Homeowners and renters must still insure their lives.
This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm and all
of its parts have passed many stringent tests and are designed to be as reliable as
possible, any of these parts could fail at any time. Therefore, you must test this
device weekly. The unit should be replaced immediately if it is not operating properly.
T
his Smoke/CO Alarm is not foolproof. Like all other electronic devices, this
S
moke/CO Alarm has limitations. It can only detect smoke or CO that reaches the
s
ensors. It may not give early warning of the source of smoke or CO is in a remote
p
art of the home, away from the alarm device.
GENERAL LIMITATIONS OF SMOKE/CO ALARMS
U
SER’S MANUAL
F
or additional coverage, it is recommended that you install a Smoke Alarm in
a
ll rooms, halls, storage areas, finished attics, and basements, where tempera-
t
ures normally remain between 40˚ F (4.4˚ C) and 100˚ F (37.8˚ C). Make sure no
d
oor or other obstruction could keep smoke from reaching the Smoke Alarms.
M
ore specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with the door partly or
c
ompletely closed.
In the hall near every sleeping area. If your home has multiple sleeping
areas, install a unit in each. If a hall is more than 40 feet long (12 meters),
install a unit at each end.
At the top of the first-to-second floor stairway, and at the bottom
o
f the basement stairway.
Specific requirements for Smoke Alarm installation vary from state to state
and from region to region. Check with your local Fire Department for current
requirements in your area. It is recommended AC or AC/DC units be
interconnected for added protection.
A
GENCY PLACEMENT RECOMMENDATIONS
Standards: Underwriters Laboratories Inc. Single and Multiple Station Smoke
Alarms 217.
N
FPA 72 Chapter 29
For your information, the National Fire Alarm and Signaling Code, NFPA 72,
r
eads as follows:”
2
9.5.1* Required Detection.
2
9.5.1.1* Where required by other governing laws, codes, or standards for a
s
pecific type of occupancy, approved single and multiple-station smoke
a
larms shall be installed as follows:
(1)*In all sleeping rooms and guest rooms
(2)*Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m)
of any door to a sleeping room, with the distance measured along a path
o
f travel
(
3) On every level of a dwelling unit, including basements
(
4) On every level of a residential board and care occupancy (small facility),
i
ncluding basements and excluding crawl spaces and unfinished attics
(
5)*In the living area(s) of a guest suite
(
6) In the living area(s) of a residential board and care occupancy
(
small facility)
(Reprinted with permission from NFPA 72
®
, National Fire Alarm and Signaling
Code Copyright © 2010 National Fire Protection Association, Quincy, MA
02269. This reprinted material is not the complete and official position of
the National Fire Protection Association, on the referenced subject which is
represented only by the standard in its entirety), (National Fire Alarm and
Signaling Code
®
and NFPA 72
®
are registered trademarks of the National
Fire Protection Association, Inc., Quincy, MA 02269).
C
ontinued...
R
ECOMMENDED PLACEMENT
When installing on the wall, the top edge of Smoke Alarms should be
p
laced between 4 inches (102 mm) and 12 inches (305 mm) from the
w
all/ceiling line.
When installing on the ceiling, place the alarm as close to the
center as possible.
In either case, install at least 4 inches (102 mm) from where the wall and
ceiling meet. See “Avoiding Dead Air Spaces” for more information.
N
OTE: For any location, make sure no door or other obstruction could keep
c
arbon monoxide or smoke from reaching the Alarm.
I
nstalling Smoke/CO Alarms in Mobile Homes
For minimum security install one Smoke/CO Alarm as close to each sleeping
area as possible. For more security, put one unit in each room. Many older
mobile homes (especially those built before 1978) have little or no insulation.
If your mobile home is not well insulated, or if you are unsure of the amount
of insulation, it is important to install units on inside walls only.
WHERE THIS ALARM SHOULD NOT BE INSTALLED
Do NOT locate this Smoke/CO Alarm:
In garages, furnace rooms, crawl spaces and unfinished attics. Avoid
e
xtremely dusty, dirty or greasy areas.
Where combustion particles are produced. Combustion particles form
when something burns. Areas to avoid include poorly ventilated kitchens,
garages, and furnace rooms. Keep units at least 20 feet (6 meters) from
the sources of combustion particles (stove, furnace, water heater, space
heater) if possible. In areas where a 20-foot (6 meter) distance is not
possible – in modular, mobile, or smaller homes, for example – it is
recommended the Smoke Alarm be placed as far from these fuel-burning
sources as possible. The placement recommendations are intended to
keep these Alarms at a reasonable distance from a fuel-burning source,
and thus reduce “unwanted” alarms. Unwanted alarms can occur if a
Smoke Alarm is placed directly next to a fuel-burning source. Ventilate
these areas as much as possible.
Within 5 feet (1.5 meters) of any cooking appliance. In air streams near
kitchens. Air currents can draw cooking smoke into the smoke sensor
a
nd cause unwanted alarms.
In extremely humid areas. This Alarm should be at least 10 feet (3 meters)
from a shower, sauna, humidifier, vaporizer, dishwasher, laundry room,
utility room, or other source of high humidity.
In direct sunlight.
In turbulent air, like near ceiling fans or open windows. Blowing air may
p
revent CO or smoke from reaching the sensors.
In areas where temperature is colder than 40˚ F (4.4˚ C) or hotter than
100˚F (37.8˚ C). These areas include non-airconditioned crawl spaces,
unfinished attics, uninsulated or poorly insulated ceilings, porches, and
garages.
In insect infested areas. Insects can clog the openings to the sensing
c
hamber.
Less than 12 inches (305 mm) away from fluorescent lights. Electrical
noise” can interfere with the sensor.
In “dead air” spaces. See “Avoiding Dead Air Spaces”.
AVOIDING DEAD AIR SPACES
“Dead air” spaces may prevent smoke from reaching the Smoke/CO Alarm.
To avoid dead air spaces, follow installation recommendations below.
On ceilings, install Smoke/CO Alarms as close to the center of the ceiling as
possible. If this is not possible, install the Smoke/CO Alarm at least 4 inches
(102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of Smoke/CO
Alarms should be placed between 4 inches (102 mm) and 12 inches (305 mm)
from the wall/ceiling line, below typical “dead air” spaces.
O
n a peaked, gabled, or cathedral ceiling, install first Smoke/CO Alarm
w
ithin 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally.
A
dditional Smoke/CO Alarms may be required depending on the length, angle,
e
tc. of the ceiling's slope. Refer to NFPA 72 for details on requirements for
s
loped or peaked ceilings.
INSTALLATION
WHERE TO INSTALL THIS ALARM
Minimum coverage for Smoke Alarms, as recommended by the National
Fire Protection Association (NFPA), is one Smoke Alarm on every floor, in
every sleeping area, and in every bedroom (See “Regulatory Information For
Smoke Alarms” for details on the NFPA recommendations).
For CO Alarms, the National Fire Protection Association (NFPA) recommends
that a CO Alarm should be centrally located outside of each separate sleeping
area in the immediate vicinity of the bedrooms. For added protection, install
additional CO Alarms in each separate bedroom, and on every level of your
home.
NOTE: For added protection, install an additional Smoke/CO Alarm at least
15 feet (4.6 meters) away from the furnace or fuel burning heat source where
possible. In smaller homes or in manufactured homes where this distance
cannot be maintained, install the Alarm as far away as possible from the furnace
or other fuel burning source. Installing the Alarm closer than 15 feet (4.6 meters)
will not harm the Alarm, but may increase the frequency of unwanted alarms.
In general, install combination Smoke and Carbon Monoxide Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with the door partly or
completely closed.
In the hall near every sleeping area. If your home has multiple sleeping
areas, install a unit in each. If a hall is more than 40 feet (12 meters) long,
install a unit at each end.
At the top of first-to-second floor stairs.
At the bottom of the basement stairs.
For additional coverage, install Alarms in all rooms, halls, and storage
areas, where temperatures normally remain between 40˚ F and 100˚ F
(4.4˚ C and 37.8˚ C).
H
OW TO INSTALL THIS ALARM
This combination Smoke/CO Alarm was designed to be mounted on the
ceiling or wall. It is not a tabletop device. You must install this device on the
ceiling or wall as outlined below. Read “Where To Install This Alarm” before
starting.
Tools you will need: pencil, drill with 3/16” or 5mm drill bit,
flathead screwdriver, hammer.
Do not connect this unit to any other alarm or auxiliary device. It is a
single-station unit that cannot be linked to other devices. Connecting
anything else to this unit may prevent it from working properly.
Do not install this unit over an electrical junction box. Air currents
around junction boxes can prevent smoke from reaching the sens-
ing chamber and prevent the unit from alarming. Only AC powered
units are intended for installation over junction boxes.
If you want to lock the battery compartment, or lock the Smoke/CO
Alarm to the mounting bracket, please read the “Optional Locking
Features” section.
1. Hold base firmly and twist the mounting bracket counterclockwise (left) to
separate it from the unit.
2. Hold the mounting bracket against the ceiling (or wall) so the vertical
mounting slot is aligned in the 12 o’clock position and trace around the
i
nside of the mounting slots (vertical and horizontal mounting).
3. Put the unit where it won’t get covered with dust when you drill the
mounting holes.
4. Using a 3/16” (5 mm) drill bit, drill a hole through the center of the oval
outlines you traced.
5. Insert the plastic screw anchors (in the plastic bag with screws) into the
holes. Tap the screw anchors gently with a hammer, if necessary, until
they are flush with the ceiling or wall.
6. Line the mounting bracket up over the plastic screw anchors.
7. Screw the mounting bracket to the ceiling or wall through the mounting
slots using the two screws provided.
8. Before attaching the Alarm to
the bracket, insert the two (2)
AA batteries (included) into the
battery compartment. Match
the terminals on the end of the
battery with the terminals on
the unit. Match “+” to “+” and
“-” to “-.” If the batteries are
not fully inserted, the unit
cannot receive battery power.
N
OTE: The unit may beep briefly when you install the batteries. This is normal.
T
he GREEN Light flashes about every 60 seconds when the unit is
r
eceiving battery power.
T
he battery door will resist closing unless batteries are installed. This
w
arns you the unit will not operate without batteries.
9
. Attach the Smoke/CO Alarm to the
m
ounting bracket. Line up the guides on
t
he alarm’s base with the guides on the
m
ounting bracket. When guides are lined
u
p, turn the base clockwise (right) until it
s
naps into place.
N
OTE: Once the Smoke/CO Alarm is
s
napped onto the mounting bracket,
y
ou can rotate the Smoke/CO Alarm
t
o adjust the alignment.
10. Test the Smoke/CO Alarm. See “Weekly
Testing” for details.
S
UGGESTED AREAS FOR INSTALLING 
SMOKE ALARMS, CO ALARMS, AND COMBO UNITS
S
MOKE ALARM WITH 
SILENCE FEATURE
CO ALARMS
BOTH, OR COMBINATION 
S
MOKE/CO ALARMS
SMOKE ALARMS
KEY:
Suggested locations are based on
NFPA recommendations (NFPA 72 
f
or Smoke Alarms and NFPA 720 for
Carbon Monoxide Alarms). Always 
refer to national and local codes 
before beginning any installation.
In new construction AC and AC/DC smoke alarms MUST
b
e interconnected to meet NFPA recommendations.
Type of Alarm
C
arbon Monoxide (CO)
What You See and Hear
C
O LED: Flashes Red
Horn: 4 beeps, pause, 4 beeps, pause
Power/Smoke LED: Off
Smoke Power/Smoke LED: Flashes Red
Horn: 3 beeps, pause, 3 beeps, pause
C
O LED: Off
I
F THE CO ALARM SOUNDS
A
ctuation of your CO Alarm indicates the presence of carbon monoxide
(
CO) which can kill you. In other words, when your CO Alarm sounds,
y
ou must not ignore it!
I
F THE CO ALARM SIGNAL SOUNDS:
1
. Operate the Test/Silence button.
2. Call your emergency services, fire department or 911. Write down the
number of your local emergency service here:
__________________________________________________________________
3. Immediately move to fresh air—outdoors or by an open door or window.
Do a head count to check that all persons are accounted for. Do not re-
enter the premises, or move away from the open door or window until the
emergency services responder has arrived, the premises have been aired
out, and your CO Alarm remains in its normal condition.
4
. After following steps 1-3, if your CO Alarm reactivates within a 24-hour
p
eriod, repeat steps 1-3 and call a qualified appliance technician to inves-
t
igate for sources of CO from fuel-burning equipment and appliances, and
i
nspect for proper operation of this equipment. If problems are identified
d
uring this inspection have the equipment serviced immediately. Note any
c
ombustion equipment not inspected by the technician, and consult the
m
anufacturers’ instructions, or contact the manufacturers directly, for more
i
nformation about CO safety and this equipment. Make sure that motor
v
ehicles are not, and have not, been operating in an attached garage or
a
djacent to the residence. Write down the number of a qualified appliance
t
echnician here:
_
_________________________________________________________________
N
OTE: A qualified appliance technician is defined as “a person, firm, corpora-
t
ion, or company that either in person or through a representative, is engaged
i
n and responsible for the installation, testing, servicing, or replacement of
h
eating, ventilation, air conditioning (HVAC) equipment, combustion appliances
a
nd equipment, and/or gas fireplaces or other decorative combustion
e
quipment.”
ALARM-MOVE TO FRESH AIR”
I
f you hear the CO alarm horn and the CO red light is flashing, move
e
veryone to a source of fresh air. DO NOT remove the batteries!
IF THE SMOKE ALARM SOUNDS
R
ESPONDING TO AN ALARM
If the unit alarms and you are not testing the unit, it is warning you
of a potentially dangerous situation that requires your immediate
attention. NEVER ignore any alarm. Ignoring the alarm may result in
injury or death.
Never remove the batteries from a battery operated Smoke/CO
A
larm to stop an unwanted alarm (caused by cooking smoke, etc.).
R
emoving batteries disables the alarm so it cannot sense smoke,
a
nd removes your protection. Instead open a window or fan the
s
moke away from the unit. The alarm will reset automatically.
If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don’t stop to get
dressed or collect anything.
• Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
• Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
• Call the Fire Department as soon as possible from outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "General Limitations of Smoke/CO
Alarms" for details.
USING THE SILENCE FEATURES
Never remove the batteries to quiet an unwanted alarm. Removing the
batteries disables the alarm and removes your protection.
The Silence Feature is intended to temporarily silence the horn while you identify
and correct the problem. Do not use the Silence Feature in emergency situations.
It will not correct a CO problem or extinguish a fire.
The Silence Feature can temporarily quiet an unwanted alarm for several minutes.
Press the Test/Silence button on the alarm cover for at least 3-5 seconds.
After the Test/Silence button is released, the Red LED blinks during the silence
mode.
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning “chirp” for
up to 8 hours. Press the Test/Silence button on the alarm cover.
Once the low battery warning “chirp” silence feature is activated, the unit
continues to flash the Green light once a minute for 8 hours. After 8 hours,
the low battery “chirp” will resume. Replace the batteries as soon as
possible; this unit will not operate without battery power!
To deactivate this feature: Press the Test/Silence button again. The unit will
go into Test Mode and the low battery warning will resume (LED flashes and
unit sounds “chirp” once a minute).
REGULAR MAINTENANCE
T
his unit has been designed to be as maintenance-free as possible, but there
a
re a few simple things you must do to keep it working properly.
Test it at least once a week.
Clean the Smoke/CO Alarm at least once a month; gently vacuum the
o
utside of the Smoke/CO Alarm using your household vacuum’s soft
b
rush attachment. A can of clean compressed air (sold at computer or
o
ffice supply stores) may also be used. Follow manufacturer instructions
f
or use. Test the Smoke/CO Alarm. Never use water, cleaners or solvents
s
ince they may damage the unit.
If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust
a
nd/or grime, and cannot be cleaned to avoid unwanted alarms, replace
t
he unit immediately.
Continued...
R
EGULAR MAINTENANCE, Continued
Relocate the unit if it sounds frequent unwanted alarms. See “Where This
Alarm Should Not Be Installed” for details.
C
hoosing a replacement battery:
Your Smoke/CO Alarm requires two standard AA batteries. The following
batteries are acceptable as replacements: Duracell MN1500. These batteries
are available at many local retail stores.
Always use the exact batteries specified by this User’s Manual.
DO NOT use rechargeable batteries. Clean the battery contacts and
also those of the device prior to battery installation. Install batteries
correctly with regard to polarity (+ and -).
Please dispose of or recycle used batteries properly, following any
local regulations. Consult your local waste management authority
or recycling organization to find an electronics recycling facility in
your area. DO NOT DISPOSE OF BATTERIES IN FIRE. BATTERIES
MAY EXPLODE OR LEAK.
Keep battery out of reach of children. In the event a battery is
s
wallowed, immediately contact your poison control center, your
p
hysician, or the National Battery Ingestion hotline at 202-625-3333
a
s serious injury may occur.
A
ctual battery service life depends on the Smoke/CO Alarm and the environ-
m
ent in which it is installed. All the batteries specified above are acceptable
r
eplacement batteries for this unit. Regardless of the manufacturer’s suggested
b
attery life, you MUST replace the battery immediately once the unit starts
chirping” (the “low battery warning”).
P
ARTS OF THIS SMOKE/CO ALARM
1
Test/Silence Button
2 Battery Compartment
3
Power/Smoke Alarm LED
4
CO Alarm LED
When the Smoke Alarm is Silenced When the CO Alarm is Silenced
The Smoke Alarm will remain silent for
up to 15 minutes, then return to normal
operation.
If the smoke has not cleared–or
continues to increase–the device
will go back into alarm.
The CO alarm will remain silent for
up to 4 minutes.
After 4 minutes, if CO levels remain
potentially dangerous the horn will
start sounding again.
To replace the batteries (without removing
Alarm from the ceiling or wall):
1
. Open the battery compartment.
2
. Press tabs A and B as shown in the diagram
a
nd remove each battery.
3. Insert the new batteries, making sure they
snap completely into the battery compartment.
Match the terminals on the ends of the
batteries with the terminals on the unit.
4. Close the battery compartment, and then test
the unit by pressing the Test/Silence button.
A
B
I
F YOUR SMOKE/CO ALARM SOUNDS
WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you
activate the battery and test the Smoke/CO
Alarm.
1. Install the batteries before attaching the Alarm
to the bracket. Insert the two (2) AA batteries
(included) into the battery compartment. Match
the terminals on the end of the battery with the
terminals on the unit. Match “+” to “+” and “-”
to “-.” If the batteries are not fully inserted, the
unit cannot receive battery power.
2. Push and hold Test/Silence button until the
alarm sounds.
If the unit does not alarm during testing, DO
NOT lock the battery compartment! Install new
batteries and test again. If the unit still does
not alarm, replace it immediately.
3. Using needle-nose pliers or a utility knife,
detach one locking pin from the mounting
bracket.
4. Push the locking pin through the hole near
the battery door latch on the back of the
Smoke/CO Alarm.
OPTIONAL LOCKING FEATURES
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers or a utility knife,
detach one locking pin from the mounting
bracket.
2. Insert the locking pin through the hole
on the back of the Smoke/CO Alarm as
shown in the diagram.
3. When you attach the Smoke/CO Alarm to
the mounting bracket, the locking pin’s
head will fit into a notch on the bracket.
T
he optional locking features are designed to discourage unauthorized removal of the batteries or Alarm. It is not necessary to activate the locks in
s
ingle-family households where unauthorized battery or Alarm removal is not a concern.
This Smoke/CO Alarm has two separate locking features: one to lock the battery compartment, and the other to lock the
Smoke/CO Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.
Tools you will need: Needle-nose pliers or utility knife • Standard flathead screwdriver.
B
oth locking features use locking pins, which are molded into the mounting bracket. Depending on which locking features you
u
se, remove one or both pins from the mounting bracket using needle-nose pliers or a utility knife.
T
o permanently remove either locking pin, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
TO UNLOCK THE BATTERY COMPARTMENT
1. Remove the Smoke/CO Alarm from the
mounting bracket. If the unit is locked to
the bracket, see the section “To Unlock
the Mounting Bracket.”
2. Insert a flathead screwdriver under the
head of the locking pin, and gently pry it out
of the battery compartment lock. (If you plan
to relock the battery compartment, save the
locking pin.)
3. To relock the battery compartment, close
the battery door and reinsert locking pin in
lock.
4. Reattach the Smoke/CO Alarm to the
mounting bracket.
When replacing the batteries, always test
the Smoke/CO Alarm before relocking the
battery compartment.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a flathead screwdriver into the
rectangular cut-out on the mounting
bracket nearest to the locking pin.
2. Pry the Smoke/CO Alarm away from the
bracket by pushing up on the screwdriver and
turning the Smoke/CO Alarm counterclockwise
(left) at the same time.
NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. The
built-in test switch accurately tests the unit’s operation as required
by Underwriters Laboratories, Inc. (UL). NEVER use vehicle exhaust!
Exhaust may cause permanent damage and voids your warranty.
DO NOT stand close to the Alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working
properly. Using the test button is the recommended way to test this
Smoke/CO Alarm.
You can test this Smoke/CO Alarm: Press and hold the Test/Silence button
3-5 seconds until unit starts to alarm.
During testing, you will see and hear the following sequence:
The Horn will sound 3 beeps, pause, 3 beeps. The Power/Smoke LED
flashes Red and the CO LED will be Off.
Next the Horn will sound 4 beeps, pause, 4 beeps. The Power/Smoke
LED will be Off and the CO LED flashes Red.
If the unit does not alarm, make sure the batteries are correctly installed,
and test again. If the unit still does not alarm, replace it immediately.
C
ONFORMS TO
UL STD 217
AND
U
L STD 2034
SILENCING THE END OF LIFE SIGNAL
This silence feature can temporarily quiet the End of Life warning “chirp” for
up to 2 days. You can silence the End of Life warning “chirp” by pressing the
Test/Silence button. The horn will chirp, acknowledging that the End of Life
silence feature has been activated.
After approximately 2 days, the End of Life “chirp” will resume.
For your records, please record:
Date Purchased: __________________Where Purchased: _____________________
Date Installed: ____________/____________Month/Year
Replace alarm 7 years after installation. Please write the date in the space
provided:
_____________/____________Month/Year
The alarm will also provide an audible End-of-Life Signal approximately
7 years after installation to remind you to replace the unit.
The End-of-Life Signal can be silenced for up to 2 days. Do not unplug the
alarm or remove the batteries until you get replacement.
WEEKLY TESTING
C
alifornia State Fire Marshal (CSFM)
E
arly warning detection is best achieved by the installation of fire detection
e
quipment in all rooms and areas of the household as follows: A Smoke Alarm
i
nstalled in each separate sleeping area (in the vicinity, but outside bedrooms),
a
nd Heat or Smoke Alarms in the living rooms, dining rooms, bedrooms,
k
itchens, hallways, finished attics, furnace rooms, closets, utility and storage
r
ooms, basements, and attached garages.
A
GENCY PLACEMENT RECOMMENDATIONS, Continued
R
ECOMMENDED LOCATIONS FOR SMOKE ALARMS, Continued
Loading ...