Error 001
Explanation: When charging or starting, other functions are not available.
Solution: Disconnect the charger or exit the start mode.
Error 110
Explanation: Charging overvoltage protection.
Solution: Disconnect the charger.
Error 111
Explanation: Charging over-voltage (secondary) protection.
Solution: Disconnect the charger.
Error 120
Explanation: Charging over temperature protection.
Solution: Wait for the product to cool down.
Error 130
Explanation: Charging under temperature protection.
Solution: Put the product at the right temperature.
Error 140
Explanation: Discharge undervoltage protection.
Solution: Connect the charger.
Error 150
Explanation: Discharge over temperature protection.
Solution: Wait for the product to cool down.
Error 160
Explanation: Discharge under temperature protection.
Solution: Put the product at the right temperature.
Error 200
Explanation: Communication abnormal.
Solution: Restart the device.
Error 310
Explanation: Air inflator short-circuit protection.
Solution: Restart the device.
Error 320
Explanation: Air inflator over-current protection.
Solution: Restart the device.
Error 330
Explanation: When starting, the current air pressure is greater than the set air pressure.
Solution: Reset the proper air pressure.
Error 410
Explanation: When starting, under-voltage protection.
Solution: Connect the charger.
Error 411
Explanation: Before starting, under-voltage protection.
Solution: Connect the charger.
Error 420
Explanation: Start over temperature protection.
Solution: Wait for the product to cool down.
Error 430
Explanation: The external battery voltage is greater than the device voltage.
Solution: 1. The display voltage is lower than 12V, and the device voltage is low. Please connect the charger to recharge.
2. If the display voltage is higher than 12V, the car battery is normal, or the car battery voltage is too high, which is not suitable for this product. Please use a jump starter that supports higher voltage.
Error 440
Explanation: Ignition clip shorted.
Solution: Connect the battery correctly.
Error 450
Explanation: Ignition clip shorted.
Solution: Connect the battery correctly.
Error 460
Explanation: Short circuit protection.
Solution: Restart the device.
Error 470
Explanation: Abnormal cell voltage drift protection.
Solution: /
Error 480
Explanation: Continuous start protection.
Solution: Wait 30 seconds and start again.